Rinnai I
-
Series Condensing Boiler Combi Manual
81
DIP
Switch #
Function
Description
OFF (Default)
ON
1
Outdoor
Temperature Sensor
Enables or Disables the
Outdoor Temperature
Sensor
Outdoor
Temperature
Sensor in Use
Outdoor
Temperature
Sensor Not in
Use
2
Thermostat Usage
Changes the mode
between Thermostat
Usage and
Central
Heating
Button
Thermostat Used
Central Heating
ON
button used.
Boiler fires based
on return water
temperature
3
DHW Recirculation
Enables the DHW
Recirculation function for
Pump 2 connection
DHW Recirculation
OFF (Pump 2
connection for
Zone Pump 2)
DHW
recirculation ON
(Pump 2
connection for
DHW Pump)
4
Simultaneous Central
Heating and
Domestic Hot Water
Enables simultaneous
operation between
Central Heating and
Domestic Hot Water
Domestic Hot
Water Priority
Simultaneous
Central Heating
and
Domestic Hot
Water Permitted
5
Gas Valve Solenoid
Shuts down the
integrated solenoid gas
valve manually
Normal Operation
Fixed Closed
6
Altitude Setting
Depends on Altitude
Sets the appropriate
elevation of the boiler
installation
7
Altitude Setting
8
Vent Type Selection
Selects the venting
material used. The boiler
is set from the factory to
be installed in a PVC
venting system. If CPVC,
PP, or other approved
venting is used, this
setting may be adjusted.
See section
“5.4
PVC
Venting Safety Switch
”
for
more information.
PVC
Other
Summary of Contents for I Series
Page 124: ...124 Rinnai I Series Condensing Boiler Combi Manual ...
Page 125: ...Rinnai I Series Condensing Boiler Combi Manual 125 ...
Page 134: ...134 Rinnai I Series Condensing Boiler Combi Manual ...
Page 135: ...Rinnai I Series Condensing Boiler Combi Manual 135 ...
Page 136: ...136 Rinnai I Series Condensing Boiler Combi Manual 800000111 3 2019 ...