69
Flexibility for venting terminations is engineered into every Rinnai unit. Note below where the
exhaust alignment position can be changed by moving the stainless steel plug for two additional
positions depending on the application. Likewise note the two positions for intake air flexibility.
Alternate Vent Termination Options
ALTERNATIVE TERMINATION CONNECTION
1. Remove the plug from the back
of the termination
2. Reposition the plug to the
bottom of the termination
where labeled “exhaust”
3. Extension venting or
elbows can now be
connected to the back of
the termination
NOTE: The elbow that is integrated into the termination DOES NOT count as one of the two elbows allowable
Summary of Contents for Energysaver ES38