45
FLUE MANIFOLD DISASSEMBLY
Vent Termination
• The flue manifold consists of 3 parts:
•
Inside connection
•
Sleeve
•
Outside terminal
1. Disassemble the flue manifold by first
pulling out the inside connection.
2. To remove the outer terminal
pull and release the two
internal stainless steel ties
and then pull out the outer
terminal.
NOTE: Make sure the
black gasket is always
on the interconnector
piece as shown.