24
Rinnai America
FF Models
O P E R A T I N G I N S T R U C T I O N S
7) Turn the manual valve located at the gas
inlet of appliance counterclockwis
to “ON”.
8) Turn on all electric power to the appliance.
C A R E & L I M E C O N D I T I O N W A R N I N G
9) Set thermostat to desired setting.
10) If the appliance will not operate,
Follow the instructions “To Turn Off
Gas To Appliance” and call your
service technician or gas supplier.
To Turn Off Gas To Appliance
1) Set the thermostat to lowest setting.
2) Turn off all electric power to the appliance if service is to be performed.
3) Turn the manual valve at gas inlet of appliance clockwise
to “OFF”
Care of Unit’s Exterior:
Keep the exterior cabinet clean. Use a soft cloth and warm water when cleaning the cabinet.
Do Not
use volatile substances such as benzene and thinners, as they may ignite, or cause
fading of the paint.
Lime Condition Warning Signal:
If you notice “LC” fl ashing on the remote key pad, this means the unit is beginning to lime up,
and
MUST
be fl ushed. Contact a qualifi ed Rinnai service technician to fl ush the appliance.
Failure to fl ush the appliance when “LC” is fl ashing, will cause damage to the heat exchanger.
Damage caused by lime build up is not covered by the unit’s warranty. To reset the LC Fault
Code, turn the power off to the unit. Once power is restored, the LC code will be reset.