- 8 -
Fig. 3
•
The maximum indicated bore diameters are valid for a parallel key
connection according to DIN 6885/1 and must not be exceeded.
•
In the case of transgression of these values the coupling can
sever.
•
Through flying away fragments danger exists!
7.3 Coupling installation
•
Remove the elastic intermediate ring
(Figure 3, Pos. 1).
•
Clean the boreholes of the coupling
hubs and the shaft ends before the
installation. The surfaces must be
clean, dry and grease-free.
•
Use suitable installation aids and
hoists such as cranes or pulley
blocks in the case of bigger cou-
plings.
•
Pull the coupling hub onto the shaft
end in its intended position (Figure 3,
Pos.2).
Reference:
For easier installation a uniform warming of the hub from 80 °C to 120 °C is safe
RINGFEDER
®
TNM E
BAWN 001-
GBR