8
6. INFO
In the main menu INFO you can retrieve the most important
parameters.
Parameters
Info
Input
Output
Su 16.10.2016
15:55
Inputs
Flame temperature
[°C]
Current firebox temperature
Room temperature
[°C]
ACTUAL temperature in the room
only with RIKA roomsensor
Ext. Request
External request enabled (ON) or disabled (OFF)
Pressure switch
Sufficient low pressure in the firebox to ensure operation (ON),
or insufficient (OFF)
Grid contact
Grid in heating position (ON) or other position (OFF)
Outputs
Discharge motor [‰]
Actual speed (0 - 1000)
Discharge motor current
Actual current consumption (0 - 120)
Flue gas fan
[1/s]
Actual speed (0 - 2500)
Insertion motor
[‰]
Actual speed (0 - 1000)
Insertion motor current
Actual current consumption (0 - 120)
Air flaps
Current position (0 - 1000)
Grid motor
Actuated (ON) or in rest (OFF)
Multi Air fan
Actuated (ON) or in rest (OFF)
Multi Air fan 2
Actuated (ON) or in rest (OFF)
Ignition element
Actuated (ON) or in rest (OFF)
Parameters
Operat. hours pellets
Total operating hours in pellet mode (0 - 99999)
Feed rate total
[kg]
Total pellet feed volume (0 - 99999)
Kg till cleaning
Remaining pellets feed volume until next cleaning (1500 - 0)
Operat. h. split logs
Total operating hours in split log mode (0 - 99999)
Ignition counter
Total ignitions (0 - 99999)
ON/OFF cycles
Number of power failures
Main State
Main operating regulation state
Sub State
Secondary operating regulation state
Stove type
Name of appliance
Software stove
Software version stove control
Software display
Software version touch display