6. INFO

In  the  main  menu  INFO  you  can  retrieve  the  most  important 
parameters.

Parameters

Info

Input

Output

Su 16.10.2016

15:55

Inputs

Flame temperature 

[°C]

Current firebox temperature

Room temperature 

[°C]

ACTUAL temperature in the room

only with RIKA roomsensor

Ext. Request

External request enabled (ON) or disabled (OFF)

Pressure switch

Sufficient low pressure in the firebox to ensure operation (ON),  

or insufficient (OFF) 

Grid contact

Grid in heating position (ON) or other position (OFF)

Outputs

Discharge motor [‰]

Actual speed (0 - 1000)

Discharge motor current

Actual current consumption (0 - 120)

Flue gas fan 

[1/s]

Actual speed (0 - 2500)

Insertion motor 

[‰]

Actual speed (0 - 1000)

Insertion motor current

Actual current consumption (0 - 120)

Air flaps

Current position (0 - 1000)

Grid motor 

Actuated (ON) or in rest (OFF)

Multi Air fan

Actuated (ON) or in rest (OFF)

Multi Air fan 2

Actuated (ON) or in rest (OFF)

Ignition element

Actuated (ON) or in rest (OFF)

Parameters

Operat. hours pellets

Total operating hours in pellet mode (0 - 99999)

Feed rate total 

[kg]

Total pellet feed volume (0 - 99999)

Kg till cleaning

Remaining pellets feed volume until next cleaning (1500 - 0)

Operat. h. split logs

Total operating hours in split log mode (0 - 99999)

Ignition counter

Total ignitions (0 - 99999)

ON/OFF cycles

Number of power failures

Main State

Main operating regulation state

Sub State

Secondary operating regulation state

Stove type

Name of appliance

Software stove

Software version stove control

Software display

Software version touch display

Summary of Contents for V2.23

Page 1: ...Touch Display V2 23 2 25 Operating Instructions ...

Page 2: ...ting up without electrical ignition 6 5 SETTINGS 7 Heating times 7 Multi Air fan 7 Frost protection 7 RIKA room sensor 7 RIKA firenet 7 GSM 7 Screen Saver 7 Child lock 7 Date time 7 Language 7 Resets 7 Logging 7 Service 7 6 INFO 8 Inputs 8 Outputs 8 Parameters 8 7 EXTENDED OPERATING MODES PELLETS LOGS 9 Correct heating up 9 Automatic log operation 9 Eco Operation 9 Log operation in case of power b...

Page 3: ... sensor available on request Q RIKA GSM Control available on request USB connection Q Flash drive included in the delivery Q RIKA firenet available on request First steps Note Manipulations on hardware components may only be performed by a trained expert dealer or our customer service Inappropriate handling of these parts will void contractual and legal warranty claims Note The appliance may only ...

Page 4: ...ng times Multi air frost protection RIKA room sensor INFO Display flame temperature total operating hours total ignitions software version Standard functions Each stove model provides the following standard functions Decreases the heating output Increases the heating output Off Start Standby Note To avoid involuntary starting or switching off either button must be depressed for 2 seconds Note If y...

Page 5: ...additional functions Hide additional functions Switching to the Eco mode of operation Active info The Active info displays whether or not a module is connected or enabled HEATING TIMES standard function ROOM SENSOR only with RIKA room sensor RIKA radio room sensor GSM only with RIKA GSM Controlo FROST PROTECTION only with RIKA room sensor RIKA radio room sensor RIKA firenet only with RIKA firenet ...

Page 6: ...e STOVE OFF it is not possible to start up the stove Comfort mode During the heating times as saved your stove keeps a nominal room temperature preset by you Outside the heating times it is possible to adjust a setback temperature If the room temperature drops below the adjusted setback temperature your stove will start outside the saved heating times as well In this operating mode heating times m...

Page 7: ...heating power over to Level 1 min and level 5 max Fan area In addition it is possible to adapt the Multi Air fan speed AUTO level 1 to level 5 within 30 of fan speed Frost protection Only possible if a roomsensor is connected If this function is enabled ON and if the room temperature drops below the set value 0 C 10 C your stove will start working This applies also outside the heating times and in...

Page 8: ... speed 0 1000 Insertion motor current Actual current consumption 0 120 Air flaps Current position 0 1000 Grid motor Actuated ON or in rest OFF Multi Air fan Actuated ON or in rest OFF Multi Air fan 2 Actuated ON or in rest OFF Ignition element Actuated ON or in rest OFF Parameters Operat hours pellets Total operating hours in pellet mode 0 99999 Feed rate total kg Total pellet feed volume 0 99999 ...

Page 9: ...ighter on top of the chipboard If necessary some uncoated paper can be placed under the chipboard instead of the firelighter Now set the RIKA firelighter or the uncoated paper alight and close the firebox door Note Be sure that the combustion trough is empty as the grid will tip after the firebox door has been closed Tip The RIKA firelighter no E15834 is available from your RIKA dealer Automatic l...

Page 10: ...gh to facilitate burning Close firebox door Start stove operation After ignition has been successful the operating state IGNITION switches to LOG CHECK and after successful log recognition to LOG OPERATION Note If no more logs are reloaded pellet operation starts automatically again as the unit is still on Automatic log detection during operation Open the firebox door and place 2 logs into the box...

Page 11: ...e pellet hopper lid is open The firebox door is open The firebox door and or the pellet hopper lid are open Solution Close pellet hopper lid Close firebox door Close firebox door and or pellet hopper lid Warning Please pull down lever WARNING BURNBACK AND FLUE GAS FLAP Please pull down lever FLUE GAS FLAP OPEN WARNING NOT ENOUGH LOW PRESSURE Please check pressure WARNING Meaning Burn back flap and...

Page 12: ...or and or the pellet hopper lid have not been closed Ignition cycle has failed The turning grid cannot complete his tipping cycle Solution Close firebox door and or pellet hopper lid and quit error message Evacuate or clean combustion trough and the ingnition tube Quit error message Check for blocking of grid in the combustion trough area and quit error message Error ERROR 05 FLAMESENSOR DEFECT ER...

Page 13: ... Depending on model unblock press the safety temperature limiter on rear side of stove check the operation of the convection air fan in the CONTROL MODE state Error ERROR 15 COMM DISCHARGE BOARD ERROR 16 COMM INSERTION BOARD ERROR 17 COMM AIR FLAPS BOARD No 15 16 17 Meaning The discharge motor cannot be actuated properly The insertion motor cannot be actuated properly The air flaps cannot be actua...

Page 14: ...e Technical and design changes as well as typesetting and printing errors reserved 2018 RIKA Innovative Ofentechnik GmbH Z36223_EN_TouchDisplay_V2 23 2 25 27 08 2018 RIKA Innovative Ofentechnik GmbH Müllerviertel 20 4563 Micheldorf AUSTRIA Tel 43 0 7582 686 41 Fax 43 E Mail verkauf rika at www rika at ...

Reviews: