background image

12

Error messages

If an error occurs, your stove switches over to the operating state 

BURN-OFF

. After the appropriate measure has been taken, your stove is 

ready for operation again.

Note

If the error messages appear again and again, please contact the customer service without delay. 

Error

ERROR #00

NO
PELLET

PELLET HOPPER
LID OPEN

ERROR #01

ERROR 

#02

DOOR
OPEN

No.

#00

#1

#2

Meaning

Insufficient amount of pellets in hopper. Pellet hopper lid has not been closed.

Firebox door has not been closed.

Solution

Top up pellets and quit error message.

The  ignition  cycle  to  follow  will  last 
longer as first the pellet auger has to be 
refilled.

Close  pellet  hopper  lid  and  quit  error 
message.

Close  firebox  door  and  quit  error 
message.

Error

DOOR OR
PELLET HOPPER
LID OPEN

Please close doors

ERROR 

#01/02

ERROR #03

NOT
IGNITED

ERROR #04

GRID
DEFECT

No.

#01/02

#3

#4

Meaning

Firebox  door  and/or  the  pellet  hopper 
lid have not been closed.

Ignition cycle has failed.

The  turning  grid  cannot  complete  his 
tipping cycle. 

Solution

Close firebox door and/or pellet hopper 
lid and quit error message.

Evacuate  or  clean  combustion  trough 
and  the  ingnition  tube.  Quit  error 
message.

Check  for  blocking  of  grid  in  the 
combustion trough area and quit error 
message.

Error

ERROR #05

FLAMESENSOR
DEFECT

ERROR #06

DISCHARGE MOTOR
DEFECT

ERROR #07

INSERTION MOTOR
DEFECT

No.

#5

#6

#7

Meaning

The  firebox  temperature  cannot  be 
measured.

The  discharge  motor  cannot  be 
actuated properly.

The insertion motor cannot be actuated 
properly.

Solution

Clean  flame  temperature  probe  and 
acknowledge error message.

Quit error message.

Quit error message.

Error

ERROR #08

DISCHARGE MOTOR
JAMMED

ERROR #09

INSERTION MOTOR
JAMMED

ERROR #10

AIR FLAPS
DEFECT

No.

#8

#9

#10

Meaning

The discharge motor is blocked.

The insertion motor is blocked.

The air flaps are not in correct position.

Solution

Further  operation  not  possible,  please 
inform customer service.

Quit error message.

Quit error message.

Summary of Contents for V2.23

Page 1: ...Touch Display V2 23 2 25 Operating Instructions ...

Page 2: ...ting up without electrical ignition 6 5 SETTINGS 7 Heating times 7 Multi Air fan 7 Frost protection 7 RIKA room sensor 7 RIKA firenet 7 GSM 7 Screen Saver 7 Child lock 7 Date time 7 Language 7 Resets 7 Logging 7 Service 7 6 INFO 8 Inputs 8 Outputs 8 Parameters 8 7 EXTENDED OPERATING MODES PELLETS LOGS 9 Correct heating up 9 Automatic log operation 9 Eco Operation 9 Log operation in case of power b...

Page 3: ... sensor available on request Q RIKA GSM Control available on request USB connection Q Flash drive included in the delivery Q RIKA firenet available on request First steps Note Manipulations on hardware components may only be performed by a trained expert dealer or our customer service Inappropriate handling of these parts will void contractual and legal warranty claims Note The appliance may only ...

Page 4: ...ng times Multi air frost protection RIKA room sensor INFO Display flame temperature total operating hours total ignitions software version Standard functions Each stove model provides the following standard functions Decreases the heating output Increases the heating output Off Start Standby Note To avoid involuntary starting or switching off either button must be depressed for 2 seconds Note If y...

Page 5: ...additional functions Hide additional functions Switching to the Eco mode of operation Active info The Active info displays whether or not a module is connected or enabled HEATING TIMES standard function ROOM SENSOR only with RIKA room sensor RIKA radio room sensor GSM only with RIKA GSM Controlo FROST PROTECTION only with RIKA room sensor RIKA radio room sensor RIKA firenet only with RIKA firenet ...

Page 6: ...e STOVE OFF it is not possible to start up the stove Comfort mode During the heating times as saved your stove keeps a nominal room temperature preset by you Outside the heating times it is possible to adjust a setback temperature If the room temperature drops below the adjusted setback temperature your stove will start outside the saved heating times as well In this operating mode heating times m...

Page 7: ...heating power over to Level 1 min and level 5 max Fan area In addition it is possible to adapt the Multi Air fan speed AUTO level 1 to level 5 within 30 of fan speed Frost protection Only possible if a roomsensor is connected If this function is enabled ON and if the room temperature drops below the set value 0 C 10 C your stove will start working This applies also outside the heating times and in...

Page 8: ... speed 0 1000 Insertion motor current Actual current consumption 0 120 Air flaps Current position 0 1000 Grid motor Actuated ON or in rest OFF Multi Air fan Actuated ON or in rest OFF Multi Air fan 2 Actuated ON or in rest OFF Ignition element Actuated ON or in rest OFF Parameters Operat hours pellets Total operating hours in pellet mode 0 99999 Feed rate total kg Total pellet feed volume 0 99999 ...

Page 9: ...ighter on top of the chipboard If necessary some uncoated paper can be placed under the chipboard instead of the firelighter Now set the RIKA firelighter or the uncoated paper alight and close the firebox door Note Be sure that the combustion trough is empty as the grid will tip after the firebox door has been closed Tip The RIKA firelighter no E15834 is available from your RIKA dealer Automatic l...

Page 10: ...gh to facilitate burning Close firebox door Start stove operation After ignition has been successful the operating state IGNITION switches to LOG CHECK and after successful log recognition to LOG OPERATION Note If no more logs are reloaded pellet operation starts automatically again as the unit is still on Automatic log detection during operation Open the firebox door and place 2 logs into the box...

Page 11: ...e pellet hopper lid is open The firebox door is open The firebox door and or the pellet hopper lid are open Solution Close pellet hopper lid Close firebox door Close firebox door and or pellet hopper lid Warning Please pull down lever WARNING BURNBACK AND FLUE GAS FLAP Please pull down lever FLUE GAS FLAP OPEN WARNING NOT ENOUGH LOW PRESSURE Please check pressure WARNING Meaning Burn back flap and...

Page 12: ...or and or the pellet hopper lid have not been closed Ignition cycle has failed The turning grid cannot complete his tipping cycle Solution Close firebox door and or pellet hopper lid and quit error message Evacuate or clean combustion trough and the ingnition tube Quit error message Check for blocking of grid in the combustion trough area and quit error message Error ERROR 05 FLAMESENSOR DEFECT ER...

Page 13: ... Depending on model unblock press the safety temperature limiter on rear side of stove check the operation of the convection air fan in the CONTROL MODE state Error ERROR 15 COMM DISCHARGE BOARD ERROR 16 COMM INSERTION BOARD ERROR 17 COMM AIR FLAPS BOARD No 15 16 17 Meaning The discharge motor cannot be actuated properly The insertion motor cannot be actuated properly The air flaps cannot be actua...

Page 14: ...e Technical and design changes as well as typesetting and printing errors reserved 2018 RIKA Innovative Ofentechnik GmbH Z36223_EN_TouchDisplay_V2 23 2 25 27 08 2018 RIKA Innovative Ofentechnik GmbH Müllerviertel 20 4563 Micheldorf AUSTRIA Tel 43 0 7582 686 41 Fax 43 E Mail verkauf rika at www rika at ...