10
Log operation in case of power breakdown
Note
Your stove must be disconnected from the mains for current-free
operation.
Note
Any modification of the procedure stated above may result in
damaging of components, which automatically will void any
warranty claims.
Insert the socket spanner supplied in the sleeve, as shown.
Turn it clockwise until a slight stop can be felt.
Remove the socket spanner from the opening and insert it again in
horizontal position.
Turn the spanner ant-clockwise until it is flush with the marking in
the side panel (approx. 45°). It is now in heating up position.
After heating-up has been successful, turn the spanner anti-
clockwise step by step to reduce the combustion air manually, thus
regulating the burn-off.
Each time logs are added, the spanner must be brought into heating
up positon again. The combustion air is regulated as described
above.
Note
Always ensure that the stove has enough air for combustion. Clean
the fire trough manually.
Combined operation
Automatic ignition of firewood during start-up, or automatic log
recognition during operation.
Automatic ignition of firewood during start-up
Place two logs into the firebox. Be sure that at least one of the logs
lays above the combustion trough to facilitate burning. Close firebox
door.
Start stove operation. After ignition has been successful, the
operating state
IGNITION
switches to
LOG CHECK
, and after
successful log recognition to
LOG OPERATION
.
Note
If no more logs are reloaded, pellet operation starts automatically
again as the unit is still on.
Automatic log detection during operation
Open the firebox door and place 2 logs into the box. Be sure that
at least one of the logs lays above the ignition trough to facilitate
burning.
Close firebox door. The operating state switches from
CONTROLLED OPERATION
to
LOG CHECK
, and after successful log
recognition to
LOG OPERATION
.
Note
If no more logs are reloaded, pellet operation restarts automatically
as the unit is still on.
If you switch the combi stove off during log operation, the operating
state will change to
STOVE OFF
after the logs have burned down.
Easy-refilling operation
In order to reduce the discharge of fluegas when refilling logs there
is a easy-refilling operation available.
unhide additional
functions
hide additional
functions
Open the fluegas
flap
Wait about 3 seconds before you open the combustion chamber
door to refuel.
After closing the combustion chamber door, turn the wrench
clockwise to close the fluegasflap.
Tip
If the flue gas flap is open, a warning appears on the display. It
expires when you close the flue gas flap.
Note
Pellet operation is not possible with an opened flue gas flap.