background image

10

Log operation in case of power breakdown

Note

Your stove must be disconnected from the mains for current-free 
operation.

Note

Any  modification  of  the  procedure  stated  above  may  result  in 
damaging  of  components,  which  automatically  will  void  any 
warranty claims. 

Insert the socket spanner supplied in the sleeve, as shown.

Turn it clockwise until a slight stop can be felt.

Remove the socket spanner from the opening and insert it again in 
horizontal position. 

Turn the spanner ant-clockwise until it is flush with the marking in 
the side panel (approx. 45°). It is now in heating up position.

After  heating-up  has  been  successful,  turn  the  spanner  anti-
clockwise step by step to reduce the combustion air manually, thus 
regulating the burn-off. 

Each time logs are added, the spanner must be brought into heating 
up  positon  again.  The  combustion  air  is  regulated  as  described 
above.

Note

Always ensure that the stove has enough air for combustion. Clean 
the fire trough manually.

Combined operation

Automatic  ignition  of  firewood  during  start-up,  or  automatic  log 
recognition during operation.

Automatic ignition of firewood during start-up

Place two logs into the firebox. Be sure that at least one of the logs 
lays above the combustion trough to facilitate burning. Close firebox 
door.

Start  stove  operation.  After  ignition  has  been  successful,  the 
operating  state 

IGNITION

  switches  to 

LOG  CHECK

,  and  after 

successful log recognition to 

LOG OPERATION

.

Note

If no more logs are reloaded, pellet operation starts automatically 
again as the unit is still on.

Automatic log detection during operation

Open  the  firebox  door  and  place  2  logs  into  the  box.  Be  sure  that 
at  least  one  of  the  logs  lays  above  the  ignition  trough  to  facilitate 
burning.

Close  firebox  door.  The  operating  state  switches  from  

CONTROLLED OPERATION

 to 

LOG CHECK

, and after successful log 

recognition to 

LOG OPERATION

.

Note

If no more logs are reloaded, pellet operation restarts automatically 
as the unit is still on.

If you switch the combi stove off during log operation, the operating 
state will change to 

STOVE OFF

 after the logs have burned down.

Easy-refilling operation

In order to reduce the discharge of fluegas when refilling logs there 
is a easy-refilling operation available. 

unhide additional 
functions

hide additional 
functions

Open the fluegas 
flap

Wait  about  3  seconds  before  you  open  the  combustion  chamber 
door to refuel.

After  closing  the  combustion  chamber  door,  turn  the  wrench 
clockwise to close the fluegasflap.

Tip

If  the  flue  gas  flap  is  open,  a  warning  appears  on  the  display.  It 
expires when you close the flue gas flap.

Note

Pellet operation is not possible with an opened flue gas flap.

Summary of Contents for V2.23

Page 1: ...Touch Display V2 23 2 25 Operating Instructions ...

Page 2: ...ting up without electrical ignition 6 5 SETTINGS 7 Heating times 7 Multi Air fan 7 Frost protection 7 RIKA room sensor 7 RIKA firenet 7 GSM 7 Screen Saver 7 Child lock 7 Date time 7 Language 7 Resets 7 Logging 7 Service 7 6 INFO 8 Inputs 8 Outputs 8 Parameters 8 7 EXTENDED OPERATING MODES PELLETS LOGS 9 Correct heating up 9 Automatic log operation 9 Eco Operation 9 Log operation in case of power b...

Page 3: ... sensor available on request Q RIKA GSM Control available on request USB connection Q Flash drive included in the delivery Q RIKA firenet available on request First steps Note Manipulations on hardware components may only be performed by a trained expert dealer or our customer service Inappropriate handling of these parts will void contractual and legal warranty claims Note The appliance may only ...

Page 4: ...ng times Multi air frost protection RIKA room sensor INFO Display flame temperature total operating hours total ignitions software version Standard functions Each stove model provides the following standard functions Decreases the heating output Increases the heating output Off Start Standby Note To avoid involuntary starting or switching off either button must be depressed for 2 seconds Note If y...

Page 5: ...additional functions Hide additional functions Switching to the Eco mode of operation Active info The Active info displays whether or not a module is connected or enabled HEATING TIMES standard function ROOM SENSOR only with RIKA room sensor RIKA radio room sensor GSM only with RIKA GSM Controlo FROST PROTECTION only with RIKA room sensor RIKA radio room sensor RIKA firenet only with RIKA firenet ...

Page 6: ...e STOVE OFF it is not possible to start up the stove Comfort mode During the heating times as saved your stove keeps a nominal room temperature preset by you Outside the heating times it is possible to adjust a setback temperature If the room temperature drops below the adjusted setback temperature your stove will start outside the saved heating times as well In this operating mode heating times m...

Page 7: ...heating power over to Level 1 min and level 5 max Fan area In addition it is possible to adapt the Multi Air fan speed AUTO level 1 to level 5 within 30 of fan speed Frost protection Only possible if a roomsensor is connected If this function is enabled ON and if the room temperature drops below the set value 0 C 10 C your stove will start working This applies also outside the heating times and in...

Page 8: ... speed 0 1000 Insertion motor current Actual current consumption 0 120 Air flaps Current position 0 1000 Grid motor Actuated ON or in rest OFF Multi Air fan Actuated ON or in rest OFF Multi Air fan 2 Actuated ON or in rest OFF Ignition element Actuated ON or in rest OFF Parameters Operat hours pellets Total operating hours in pellet mode 0 99999 Feed rate total kg Total pellet feed volume 0 99999 ...

Page 9: ...ighter on top of the chipboard If necessary some uncoated paper can be placed under the chipboard instead of the firelighter Now set the RIKA firelighter or the uncoated paper alight and close the firebox door Note Be sure that the combustion trough is empty as the grid will tip after the firebox door has been closed Tip The RIKA firelighter no E15834 is available from your RIKA dealer Automatic l...

Page 10: ...gh to facilitate burning Close firebox door Start stove operation After ignition has been successful the operating state IGNITION switches to LOG CHECK and after successful log recognition to LOG OPERATION Note If no more logs are reloaded pellet operation starts automatically again as the unit is still on Automatic log detection during operation Open the firebox door and place 2 logs into the box...

Page 11: ...e pellet hopper lid is open The firebox door is open The firebox door and or the pellet hopper lid are open Solution Close pellet hopper lid Close firebox door Close firebox door and or pellet hopper lid Warning Please pull down lever WARNING BURNBACK AND FLUE GAS FLAP Please pull down lever FLUE GAS FLAP OPEN WARNING NOT ENOUGH LOW PRESSURE Please check pressure WARNING Meaning Burn back flap and...

Page 12: ...or and or the pellet hopper lid have not been closed Ignition cycle has failed The turning grid cannot complete his tipping cycle Solution Close firebox door and or pellet hopper lid and quit error message Evacuate or clean combustion trough and the ingnition tube Quit error message Check for blocking of grid in the combustion trough area and quit error message Error ERROR 05 FLAMESENSOR DEFECT ER...

Page 13: ... Depending on model unblock press the safety temperature limiter on rear side of stove check the operation of the convection air fan in the CONTROL MODE state Error ERROR 15 COMM DISCHARGE BOARD ERROR 16 COMM INSERTION BOARD ERROR 17 COMM AIR FLAPS BOARD No 15 16 17 Meaning The discharge motor cannot be actuated properly The insertion motor cannot be actuated properly The air flaps cannot be actua...

Page 14: ...e Technical and design changes as well as typesetting and printing errors reserved 2018 RIKA Innovative Ofentechnik GmbH Z36223_EN_TouchDisplay_V2 23 2 25 27 08 2018 RIKA Innovative Ofentechnik GmbH Müllerviertel 20 4563 Micheldorf AUSTRIA Tel 43 0 7582 686 41 Fax 43 E Mail verkauf rika at www rika at ...