|7

EN

6

5. SETTINGS

The  main  menu  SETTINGS  is  provided  to  set,  among  others,  the 
heating times, Multi Air blower, frost protection etc.

Heating times

Using  the  heating  times  program  you  can  operate  your  stove 
according  to  the  heating  schedule.  Activating  heating  times  (ON) 
gives access to setback temperature (only with RIKA room sensor), 
and the heating times program. 

Set Heating Times

Heating Times

Set Back Temp

Heating Times

ON

14

15:55

Tu 17.10.2017

In  the  heating  times  program,  single  weekdays,  or  a  couple  of 
weekdays can be marked simultaneously (highlighted in 

ORANGE

). 

Upon selecting heating time I or heating time II you can enter the ON 
and OFF times you require for the marked weekdays.

Weekdays that have already been programmed are highlighted in 

GREEN

 when re-accessing the heating times program. 

Heating Time II

Heating Time I

Set Heating Times

ON

OFF

##:## ##:##

Mo

Tu

We

Fr

Th

Sa

Su

20:15 21:45

15:55

Su 16.10.2016

Tip

As  soon  as  a  weekday  is  marked,  the  saved  heating  times  are 
displayed.

If  a  number  of  weekdays  are  marked,  only  the  identical  heating 
times  are  displayed.  If  the  heating  times  differ  from  each  other, 
hash keys (##:##) are displayed.

Tip

If your stove does not start up although heating times have been 
saved, please check if they are enabled (ON) and if your stove is in 

STANDBY

 operating state.

Multi Air fan

Enabling the Multi Air fan (ON) you get access to fan speed and fan 
adaptation.

Fan level

The  volume  of  convection  air  is  adjustable  from  AUTO  (adapts 
automatically according to heating power), over to Level 1 (min) and 
level 5 (max).

Fan area

In addition, it is possible to adapt the Multi Air fan speed (AUTO, level 
1 to level 5) /- 30% of fan speed.

Frost protection

Only  possible  if  a  roomsensor  is  connected.  If  this  function  is 
enabled (ON) and if the room temperature drops below the set value  
(0°C - 10°C), your stove will start working.

This applies also outside the heating times and in operating state 

STOVE OFF

.

RIKA room sensor

For  more  information  on  this  option,  please  consult  the  operating 
instructions room sensor / RIKA radio room sensor. If there is a room 
sensor built in you get access to temperture adjustment and power 
requirement.

Temperture adjustment

It is possible to adjust the temperature shown in the infomenu.

Power requirement

(factory setting 3) The heating power is adjustable from level 1 (for 
small rooms) to level 4 (for big rooms).

RIKA firenet

For  more  information  on  this  option,  please  consult  the  operating 
instructions RIKA firenet.

GSM

For  more  information  on  this  option,  please  consult  the  operating 
instructions RIKA GSM Control.

Screen Saver

Sets the time interval (OFF, from 1 min to 30 min) for activating the 
screen saver.

Child lock

If this function is enabled (ON), a 4-digit code can be saved. Now, the 
screen saver may only be disabled by entering the saved code.

Date/time

Sets date and time.

Language

Selects the desired language.

Resets

Kg till cleaning

Resets  the  supply  rate  to  700  -  1500  kg  after  a  service  has  been 
carried out. 

Factory setting

Resets all stove settings to the factory setting. 

Note

This reset may only be performed if the stove temperature is below 
80°C! 

Logging

Only for service technicians.

Service

Only for service technicians.

Summary of Contents for V2.23

Page 1: ...Touch Display V2 23 2 25 Operating Instructions ...

Page 2: ...ting up without electrical ignition 6 5 SETTINGS 7 Heating times 7 Multi Air fan 7 Frost protection 7 RIKA room sensor 7 RIKA firenet 7 GSM 7 Screen Saver 7 Child lock 7 Date time 7 Language 7 Resets 7 Logging 7 Service 7 6 INFO 8 Inputs 8 Outputs 8 Parameters 8 7 EXTENDED OPERATING MODES PELLETS LOGS 9 Correct heating up 9 Automatic log operation 9 Eco Operation 9 Log operation in case of power b...

Page 3: ... sensor available on request Q RIKA GSM Control available on request USB connection Q Flash drive included in the delivery Q RIKA firenet available on request First steps Note Manipulations on hardware components may only be performed by a trained expert dealer or our customer service Inappropriate handling of these parts will void contractual and legal warranty claims Note The appliance may only ...

Page 4: ...ng times Multi air frost protection RIKA room sensor INFO Display flame temperature total operating hours total ignitions software version Standard functions Each stove model provides the following standard functions Decreases the heating output Increases the heating output Off Start Standby Note To avoid involuntary starting or switching off either button must be depressed for 2 seconds Note If y...

Page 5: ...additional functions Hide additional functions Switching to the Eco mode of operation Active info The Active info displays whether or not a module is connected or enabled HEATING TIMES standard function ROOM SENSOR only with RIKA room sensor RIKA radio room sensor GSM only with RIKA GSM Controlo FROST PROTECTION only with RIKA room sensor RIKA radio room sensor RIKA firenet only with RIKA firenet ...

Page 6: ...e STOVE OFF it is not possible to start up the stove Comfort mode During the heating times as saved your stove keeps a nominal room temperature preset by you Outside the heating times it is possible to adjust a setback temperature If the room temperature drops below the adjusted setback temperature your stove will start outside the saved heating times as well In this operating mode heating times m...

Page 7: ...heating power over to Level 1 min and level 5 max Fan area In addition it is possible to adapt the Multi Air fan speed AUTO level 1 to level 5 within 30 of fan speed Frost protection Only possible if a roomsensor is connected If this function is enabled ON and if the room temperature drops below the set value 0 C 10 C your stove will start working This applies also outside the heating times and in...

Page 8: ... speed 0 1000 Insertion motor current Actual current consumption 0 120 Air flaps Current position 0 1000 Grid motor Actuated ON or in rest OFF Multi Air fan Actuated ON or in rest OFF Multi Air fan 2 Actuated ON or in rest OFF Ignition element Actuated ON or in rest OFF Parameters Operat hours pellets Total operating hours in pellet mode 0 99999 Feed rate total kg Total pellet feed volume 0 99999 ...

Page 9: ...ighter on top of the chipboard If necessary some uncoated paper can be placed under the chipboard instead of the firelighter Now set the RIKA firelighter or the uncoated paper alight and close the firebox door Note Be sure that the combustion trough is empty as the grid will tip after the firebox door has been closed Tip The RIKA firelighter no E15834 is available from your RIKA dealer Automatic l...

Page 10: ...gh to facilitate burning Close firebox door Start stove operation After ignition has been successful the operating state IGNITION switches to LOG CHECK and after successful log recognition to LOG OPERATION Note If no more logs are reloaded pellet operation starts automatically again as the unit is still on Automatic log detection during operation Open the firebox door and place 2 logs into the box...

Page 11: ...e pellet hopper lid is open The firebox door is open The firebox door and or the pellet hopper lid are open Solution Close pellet hopper lid Close firebox door Close firebox door and or pellet hopper lid Warning Please pull down lever WARNING BURNBACK AND FLUE GAS FLAP Please pull down lever FLUE GAS FLAP OPEN WARNING NOT ENOUGH LOW PRESSURE Please check pressure WARNING Meaning Burn back flap and...

Page 12: ...or and or the pellet hopper lid have not been closed Ignition cycle has failed The turning grid cannot complete his tipping cycle Solution Close firebox door and or pellet hopper lid and quit error message Evacuate or clean combustion trough and the ingnition tube Quit error message Check for blocking of grid in the combustion trough area and quit error message Error ERROR 05 FLAMESENSOR DEFECT ER...

Page 13: ... Depending on model unblock press the safety temperature limiter on rear side of stove check the operation of the convection air fan in the CONTROL MODE state Error ERROR 15 COMM DISCHARGE BOARD ERROR 16 COMM INSERTION BOARD ERROR 17 COMM AIR FLAPS BOARD No 15 16 17 Meaning The discharge motor cannot be actuated properly The insertion motor cannot be actuated properly The air flaps cannot be actua...

Page 14: ...e Technical and design changes as well as typesetting and printing errors reserved 2018 RIKA Innovative Ofentechnik GmbH Z36223_EN_TouchDisplay_V2 23 2 25 27 08 2018 RIKA Innovative Ofentechnik GmbH Müllerviertel 20 4563 Micheldorf AUSTRIA Tel 43 0 7582 686 41 Fax 43 E Mail verkauf rika at www rika at ...

Reviews: