4
2. TECHNICAL DOCUMENTATION - ECODESIGN
Contact details of the manufacturer
Manufacturer:
Contact:
Address:
Details of the device
Characteristics when operating with the preferred fuel
Special precautions for assembly, installation or maintenance
Characteristics when operating exclusively with the preferred fuel
P
nom
6
kW
P
min
2,5
kW
η
th,nom
92,1
%
η
th,min
95,4
%
el
max
0,02
kW
el
min
0,01
kW
el
SB
0,003
kW
P
pilot
n.A.
kW
Notified body:
Pilot flame power requirement
Notified body no.:
Technologisches Gewerbemuseum, Wexstraße 19-23, 1200
Wien, Austria
1532
Fire protection and safety distances such as distances to combustible building materials must be observed!
Direct heat output:
HL-8480
EN14785:2006
-
Nein
TECHNICAL DOCUMENTATION
according to commission regulation
(EU) 2015/1185 und 2015/1186
Ecodesign
Model Identifier:
Equivalent models:
REVIVO 125 / REVIVO 140
-
RIKA Innovative Ofentechnik GmbH
Andreas Bloderer
Müllerviertel 20
4563 Micheldorf
Austria
Test report no.:
Applied harmonised standards:
Other applied standards/technical specifications:
Indirect heating functionality:
An adequate supply of combustion air for the appliance must be guaranteed at all times. Air-suction systems can interfere with the combustion air supply!
The flue gas values of the appliance must be observed for the chimney dimensioning!
Auxiliary electricity consumption
At nominal heat output
At minimum heat output
Heat output
Nominal heat output
Minimum heat output
Useful efficiency
Useful efficiency at nominal heat output
6 kW
Indirect heat output:
Useful efficiency at minimum heat output
In standby mode
Permanent pilot flame power requirement
Energy Efficiency Index:
123
-
Seasonal space heating energy efficiency RIKATRONIC
η
s :
-
Seasonal space heating energy efficiency
η
s :
Energy Efficiency Index RIKATRONIC:
81,4 %
-
Summary of Contents for Revivo 125
Page 1: ...Operating manual REVIVO 140 REVIVO 125...