background image

|11

10

EN

Note: Please consider the powdercoated parts can differ slightly in colour and colour effects though they are elaborated in high quality�

Nr.

Art.Nr.

Description

105

N112086

Grub screw

106

N112318

Spring-loaded pressure piece

107 *2

LB00717

Front panel

108

Z37305

Opener for ventilation grid

109

LB00730

Convection fins

110

N112403

Magnet

111

N112031

Screw

112

L03488

Holder touch-display

113

B17158

Touch-display screwable

114

LB00735

Frame touch-display

115

LB00736

Display case

120

N112284

Hexagon socket screw

121

N112407

Temperatur limiter

122

L03420

Mounting plate

123

L03313

Holder temperatur limiter

124

L01954

Pressure bracket

125

B16676

Flame temperatur sensor

126

B15248

Sensor tube

127

N111551

Silicon hose

128

B18173

Pressure Pipe

129

N112274

Hexagonal nut M05

130

Z36290

Seal for ignition

131

B17166

Ceramic ignition

132

N105627

Self-tapping screw

133

B16155

Induced draft fan housing

134

Z37023

Component holder

135

N112297

Self-locking nut

136

B16561

Mainboard USB11

137

N111964

Hexagonal screw

138

L03324

Mounting bracket

139

N112402

Rocker switch

140

N111604

Fuse 2,5 A

141

L03409

Support for drag chain

142

N112394

Chain

143

N112102

Differential pressure switch

144

N103990

Allen screw M04 x08

145

N111581

Induced draft fan motor

Nr.

Art.Nr.

Description

146

B16030

Additional motherboard for motor, incl. 
cable

147

N112030

Screw motor, stepless

148

L03410

Support for motor

149

N108486

Allen screw

150

Z11915

Lock ring conveyer screw

151

N112499

Setscrew with pin

152

B18186

Retaining plate motor assy

153

L00797

Motor holder plate

154

Z18997

Rubber buffer

155

Z35182

Friction bearing Di16

156

B16967

Auger

157

Z35183

Friction bearing Di10

B18192

Wiring harness

Z37058

Cable for touch-screen 4 m

Z34841

Cable for additional motherboard

REVIVO 125

160

N112318

Spring-loaded pressure piece

161

N112027

Magnet

B18478

Push tray assy

163

N100751

Flat allen screw

164

N105575

Allen screw

165

Z37442

Opening shaft

166

L03496

Mount

167

L03499

Slide

168

Z37445

Cover push tray

169

N112009

Flat washer

170

N112497

Disc spring

171

Z37443

Hinge shaft

172

Z37444

Cover

173

B18476

Cover container lid

174

L03495

Spacer plate

175 *2

B18477

Front panel

E16475

Sealing kit

*1

till serial number 1392312

*2

requires detent plate Z37483 till serial 
number 1392312

Summary of Contents for Revivo 125

Page 1: ...Operating manual REVIVO 140 REVIVO 125...

Page 2: ...ording to ENplus A1 15 Pellet container refilling during operation 15 Pellet storage 15 6 TECHNOLOGY AND SAFETY FUNCTIONS 16 Operating comfort 16 Top efficiency lowest emissions 16 Pressure monitoring...

Page 3: ...20 Cleaning the flue pipes 21 Combustion air intake 21 Cleaning the convection air openings 21 Cleaning the pellet container 21 Checking door seal 21 Bearings 21 11 PROBLEMS POSSIBLE SOLUTIONS 22 Prob...

Page 4: ...Model Identifier Equivalent models REVIVO 125 REVIVO 140 RIKA Innovative Ofentechnik GmbH Andreas Bloderer M llerviertel 20 4563 Micheldorf Austria Test report no Applied harmonised standards Other ap...

Page 5: ...021 In case of doubt as well as missing or incorrect translations the German version is the only valid one Subject to technical and visual changes as well as layout and printing errors 2021 RIKA Innov...

Page 6: ...0 10 19 20 17 30 23 25 24 24 26 27 16 28 29 1 6 21 22 2 2 5 3 4 4 44 44 51 50 32 32 33 52 34 34 37 38 36 49 53 53 41 42 43 41 42 43 41 42 43 36 44 35 35 45 46 31 48 47 39 40 39 40 3 TECHNICAL DATA Spa...

Page 7: ...7 6 EN 64 65 66 60 61 59 61 67 62 63 58 68 69 70 71 56 57 75 81 87 91 90 85 89 88 85 86 85 93 94 82 84 83 79 92 77 78 76 80 74 73 95 96 97...

Page 8: ...100 107 106 106 104 102 105 105 109 110 114 113 112 111 115 108 157 156 155 153 154 128 129 127 126 133 145 132 152 147 148 149 150 151 125 124 121 120 123 122 130 131 134 141 146 136 138 137 137 143...

Page 9: ...9 8 EN Spare part overview exploded diagram REVIVO 125 173 160 168 172 171 170 169 166 163 165 164 161 167 174 175...

Page 10: ...Detent plate 1 Z37054 Detent plate 48 N112393 Micro switch 49 N111950 Hexagonal screw M05x10 Nr Art Nr Description 50 N105179 Hexagonal nut M10 51 L03330 Washer 52 LB00701 Rail angle right 53 Z36778 B...

Page 11: ...nting bracket 139 N112402 Rocker switch 140 N111604 Fuse 2 5 A 141 L03409 Support for drag chain 142 N112394 Chain 143 N112102 Differential pressure switch 144 N103990 Allen screw M04 x08 145 N111581...

Page 12: ...ature C 148 Chimney draft requirement Pa 3 The capacity in kg may deviate due to different pellet bulk densities The owner of small firing systems or the person authorised for the small firing system...

Page 13: ...on the stove to dry Q Laundry racks etc must be placed at a sufficient distance to the stove ACUTE DANGER OF FIRE Q When your stove is burning the use of highly inflammable and explosive materials in...

Page 14: ...ustion chamber door is to be kept closed when the stove is not in operation Q Foulingofthechimneyi e depositsofhighlyinflammablematerials such as soot and tar and subsequently fire in the chimney may...

Page 15: ...conducting measurements with a lignotester internal control Your pellet stove is only approved for the burning of pellets of tested quality Please ask your pellet stove dealer for tested fuel and a l...

Page 16: ...acknowledging the error message at the internal unit Note Maintenance and cleaning work must be performed if overheating occurs If this error recurs operation without danger is no longer guaranteed n...

Page 17: ...on must be calculated and shown with EN13384 1 and EN13384 2 Use only insulated double stainless steel tubes flexible aluminum or steel tubes are not permitted An inspection door for regular inspectio...

Page 18: ...the heating times set at the stove can also be activated You can see whether the external demand is currently activated in the INFO main menu in submenu item Info inputs If your stove receives an ext...

Page 19: ...ing cloth or newspaper Cleaning of the burn pot daily Make sure that the air vents are not blocked with ash or clinker Remove the clinker using the supplied brush and vacuum the burn pot The burn pot...

Page 20: ...Resets menu Note Yourstovemustbeswitchedoffandcooledbeforeanymaintenance work is performed Only work on the unit when the mains plug has been disconnected Cleaning the flue gas channels Disconnect yo...

Page 21: ...ush off any soot and dust deposits in the fire and in the flue pipes and vacuum Note Accumulated fly ash in the flue gas channels may impair the performance of the stove and pose a safety risk Combust...

Page 22: ...G MAINTENANCE Problem 2 Stove smells strongly and smokes outside Cause s Q Burning in phase taking into service Q Stove has accumulated dust and or dirt Possible solutions Q Wait to end of burning in...

Page 23: ...ions These are the basic stove functions that are to be checked and ticked off The stove is ready for operation if these functions are ensured Operator instruction This is one of the most important po...

Page 24: ...eight Room ventilation Exhaust hood outdoor connection WC extraction Comments Central vacuum cleaning system YES NO YES NO YES NO YES NO Chimney draft full load Outside temperature Plaster openings YE...

Page 25: ...ified for that type of stove The installation is performed by a RIKA certified technician If these points are not complied with the guarantee claim is void Any costs incurred by the manufacturer as a...

Page 26: ...eramic pane using a suitable tool Remove the seals and separate them from the frame if present Transparent glass ceramic can generally be recycled but must be separated into decorated and non decorate...

Page 27: ...27 26 EN...

Page 28: ...only valid one Subject to technical and visual changes as well as layout and printing errors 2021 RIKA Innovative Ofentechnik GmbH Z37505_REVIVO_EN 7 12 2021 RIKA Innovative Ofentechnik GmbH M llervie...