background image

|13

12

EN

4. IMPORTANT INFORMATION

General warning and safety information

Observance of the introductory general warning information is 
imperative�

 

Q

Read the entire manual thoroughly before installing and putting 
the stove into service� Observe the national provisions and laws 
as well as the regulations and rules applicable locally�

 

Q

RIKA stoves should only be installed in rooms with normal humidity 
(dry areas according to VDE 0100 Part 200)� The furnaces are not 
splash water protected and may not be installed in wet areas�

 

Q

Only approved transport equipment with sufficient load carrying 
capacity may be used with your heating appliance�

 

Q

Your heating appliance is not suitable for use as a ladder or 
stationary scaffolding�

 

Q

The burning of fuel releases heat energy that lead to extensive 
heating of the stove surfaces, doors, door and operating handles, 
glass, flue pipes and possibly the front wall� Refrain from touching 
these parts without appropriate protective clothing or equipment 
e�g� heat-resistant gloves or means of operation (operating 
handle)�

 

Q

Make your children aware of this particular danger and keep 
them away from the stove during heating�

 

Q

Only burn approved heating materials�

 

Q

The combustion or introduction of highly flammable or explosive 
materials such as empty spray cans etc� in the combustion 
chamber and storing them near the stove is strictly prohibited 
due to the danger of explosion�

 

Q

No light or inflammable clothing is to be worn when post-heating�

 

Q

Use the heat-resistant gloves supplied to open the doors of your 
stove�

 

Q

Make sure that no embers fall out of the combustion chamber 
onto inflammable material�

 

Q

Placing non-heat resistant objects on the stove or near it is 
prohibited�

 

Q

Do not place clothing on the stove to dry�

 

Q

Laundry racks etc� must be placed at a sufficient distance to the 
stove – ACUTE DANGER OF FIRE!

 

Q

When your stove is burning, the use of highly inflammable and 
explosive materials in the same or adjacent rooms is prohibited�

 

Q

If the stove is heated in continuous operation, the cleaning 
intervals are shorter� Increased wear, especially of the thermally 
stressed parts, is the result� Please therefore strictly follow the 
requirements for cleaning and maintenance!

Note

Waste and liquids may not be burnt in the stove!

Note

To prevent your stove from overheating of the internal components,
do never cover the convection fins!

Note

 

CAUTION when filling the pellet container� The opening of the pellet 
container is sufficiently dimensioned to ensure easy filling� Take 
great care that no pellets drop to the convection fins and the hot 
stove body� This can cause a lot of smoke� 

Tip

Therefore we recommend refilling the pellet container at a cold 
stove�

Note

Your stove will expand and contract during the heating and cooling 
phase� This can sometimes lead to slight bending or cracking 
noises� This is normal and is no reason for a complaint�

First heating

The stove body, just as various steel parts, cast iron parts and the 
flue pipes are painted with a heat resistant paint� During the first 
heating the paint dries out completely� This may cause a slight smell� 
Touching or cleaning the painted surfaces during the curing should 
be avoided� The hardening of the paint is finished after the first 
heating with high power� 

Safety distances

Note

In the inside space the pellet stove insert must be surrounded by 
incombustible materials�

The following safety clearances must be observed in the inside 
space:
b > 5 cm, c > 5 cm

The following safety clearances must be observed from the front:
a > 40 cm (to non-combustible objects) 
a > 80 cm (to combustible objects)

Note

When being installed in a recess, the overhang may be a maximum 
of 20 cm�

Top view:

a

a

b

b

Summary of Contents for Revivo 125

Page 1: ...Operating manual REVIVO 140 REVIVO 125...

Page 2: ...ording to ENplus A1 15 Pellet container refilling during operation 15 Pellet storage 15 6 TECHNOLOGY AND SAFETY FUNCTIONS 16 Operating comfort 16 Top efficiency lowest emissions 16 Pressure monitoring...

Page 3: ...20 Cleaning the flue pipes 21 Combustion air intake 21 Cleaning the convection air openings 21 Cleaning the pellet container 21 Checking door seal 21 Bearings 21 11 PROBLEMS POSSIBLE SOLUTIONS 22 Prob...

Page 4: ...Model Identifier Equivalent models REVIVO 125 REVIVO 140 RIKA Innovative Ofentechnik GmbH Andreas Bloderer M llerviertel 20 4563 Micheldorf Austria Test report no Applied harmonised standards Other ap...

Page 5: ...021 In case of doubt as well as missing or incorrect translations the German version is the only valid one Subject to technical and visual changes as well as layout and printing errors 2021 RIKA Innov...

Page 6: ...0 10 19 20 17 30 23 25 24 24 26 27 16 28 29 1 6 21 22 2 2 5 3 4 4 44 44 51 50 32 32 33 52 34 34 37 38 36 49 53 53 41 42 43 41 42 43 41 42 43 36 44 35 35 45 46 31 48 47 39 40 39 40 3 TECHNICAL DATA Spa...

Page 7: ...7 6 EN 64 65 66 60 61 59 61 67 62 63 58 68 69 70 71 56 57 75 81 87 91 90 85 89 88 85 86 85 93 94 82 84 83 79 92 77 78 76 80 74 73 95 96 97...

Page 8: ...100 107 106 106 104 102 105 105 109 110 114 113 112 111 115 108 157 156 155 153 154 128 129 127 126 133 145 132 152 147 148 149 150 151 125 124 121 120 123 122 130 131 134 141 146 136 138 137 137 143...

Page 9: ...9 8 EN Spare part overview exploded diagram REVIVO 125 173 160 168 172 171 170 169 166 163 165 164 161 167 174 175...

Page 10: ...Detent plate 1 Z37054 Detent plate 48 N112393 Micro switch 49 N111950 Hexagonal screw M05x10 Nr Art Nr Description 50 N105179 Hexagonal nut M10 51 L03330 Washer 52 LB00701 Rail angle right 53 Z36778 B...

Page 11: ...nting bracket 139 N112402 Rocker switch 140 N111604 Fuse 2 5 A 141 L03409 Support for drag chain 142 N112394 Chain 143 N112102 Differential pressure switch 144 N103990 Allen screw M04 x08 145 N111581...

Page 12: ...ature C 148 Chimney draft requirement Pa 3 The capacity in kg may deviate due to different pellet bulk densities The owner of small firing systems or the person authorised for the small firing system...

Page 13: ...on the stove to dry Q Laundry racks etc must be placed at a sufficient distance to the stove ACUTE DANGER OF FIRE Q When your stove is burning the use of highly inflammable and explosive materials in...

Page 14: ...ustion chamber door is to be kept closed when the stove is not in operation Q Foulingofthechimneyi e depositsofhighlyinflammablematerials such as soot and tar and subsequently fire in the chimney may...

Page 15: ...conducting measurements with a lignotester internal control Your pellet stove is only approved for the burning of pellets of tested quality Please ask your pellet stove dealer for tested fuel and a l...

Page 16: ...acknowledging the error message at the internal unit Note Maintenance and cleaning work must be performed if overheating occurs If this error recurs operation without danger is no longer guaranteed n...

Page 17: ...on must be calculated and shown with EN13384 1 and EN13384 2 Use only insulated double stainless steel tubes flexible aluminum or steel tubes are not permitted An inspection door for regular inspectio...

Page 18: ...the heating times set at the stove can also be activated You can see whether the external demand is currently activated in the INFO main menu in submenu item Info inputs If your stove receives an ext...

Page 19: ...ing cloth or newspaper Cleaning of the burn pot daily Make sure that the air vents are not blocked with ash or clinker Remove the clinker using the supplied brush and vacuum the burn pot The burn pot...

Page 20: ...Resets menu Note Yourstovemustbeswitchedoffandcooledbeforeanymaintenance work is performed Only work on the unit when the mains plug has been disconnected Cleaning the flue gas channels Disconnect yo...

Page 21: ...ush off any soot and dust deposits in the fire and in the flue pipes and vacuum Note Accumulated fly ash in the flue gas channels may impair the performance of the stove and pose a safety risk Combust...

Page 22: ...G MAINTENANCE Problem 2 Stove smells strongly and smokes outside Cause s Q Burning in phase taking into service Q Stove has accumulated dust and or dirt Possible solutions Q Wait to end of burning in...

Page 23: ...ions These are the basic stove functions that are to be checked and ticked off The stove is ready for operation if these functions are ensured Operator instruction This is one of the most important po...

Page 24: ...eight Room ventilation Exhaust hood outdoor connection WC extraction Comments Central vacuum cleaning system YES NO YES NO YES NO YES NO Chimney draft full load Outside temperature Plaster openings YE...

Page 25: ...ified for that type of stove The installation is performed by a RIKA certified technician If these points are not complied with the guarantee claim is void Any costs incurred by the manufacturer as a...

Page 26: ...eramic pane using a suitable tool Remove the seals and separate them from the frame if present Transparent glass ceramic can generally be recycled but must be separated into decorated and non decorate...

Page 27: ...27 26 EN...

Page 28: ...only valid one Subject to technical and visual changes as well as layout and printing errors 2021 RIKA Innovative Ofentechnik GmbH Z37505_REVIVO_EN 7 12 2021 RIKA Innovative Ofentechnik GmbH M llervie...

Reviews: