14
Prior to set up
Floor bearing capacity
Ensure that the substructure is capable of bearing the weight of the
stove prior to set-up�
Note
No modifications may be made to the firing installation� This also
leads to loss of warranty and guarantee�
Floor protection
A glass, sheet steel or ceramic plate is recommended, if the floor is
combustible (wood, carpet, etc�)� Please observe the respective local
regulations and rules�
Flue pipe connection
Q
Flue pipes pose a particular source of hazard regarding gas leaks
and fire� Get the advice of an authorised specialist company for
the layout and assembly�
Q
Please observe the corresponding installation guidelines for walls
panelled with wood when connecting your flue pipes to the stove�
Q
Observe the formation of flue gas (atmospheric inversion) and
draughts when the weather is unfavourable�
Q
Infeed of too little combustion air can lead to smoke in the rooms
or to flue gas leaks� Hazardous deposits in the stove and chimney
may also occur�
Q
If flue gas escapes, let the fire burn out and check whether all the
air inlet openings are free and the flue gas pipes and the stove
pipe are clean� If in doubt notify the master chimney sweep since
draught malfunctions may be connected to your chimney�
The correct chimney connection
There are several ways to connect your stove to the chimney, eg:
1) wind break, 2) chimney, 3) inspection opening
For the selection of the connection and to ensure a proper connection
between the stove and chimney, please read the guide „INSTALLING
THE STOVE“ or ask your local chimney sweep�
Stoves type 1 (BA 1):
Q
Suitable for multiple occupancy� (Note the different country
regulations�)
Q
These may only be operated with the combustion chamber door
closed�
Q
The combustion chamber door is to be kept closed when the
stove is not in operation�
Q
Fouling of the chimney i�e� deposits of highly inflammable materials
such as soot and tar and subsequently fire in the chimney may
occur if the chimney is miscalculated and dimensioned wrong�
Q
If this occurs, disconnect the mains plug� Phone the fire brigade
and get yourself and other residents out of harm’s way�
Note
Your pellet stove has been tested as a room-air independent stove
according to EN14785� It can be operated room air dependent or
room air independent�
ROOM-AIR INDEPENDENT OPERATION:
The stove is certificated for type FC52x / FC62x of the approval
principles for the inspection and evaluation of ambient air
independent fireplaces specified by the Deutsches Institut für
Bautechnik (DIBT) (German Institute for Building Technology)�
Thanks to an air-tight configuration of the air supply line and flue
pipes the stove may be operated in air-tight rooms and in rooms
with room-air installations (e�g� controlled ventilation and venting
systems, extractors etc�)�
ROOM-AIR DEPENDENT OPERATION:
In combination with room-air installations (e�g� controlled
ventilation and venting systems (extractors etc�) it must
be ensured that the stove and the room air system are
monitored and safeguarded mutually (e�g� via a differential
pressure controller)� The combustion air infeed of approx�
20 m
3
/h must be ensured�
Please observe the respective local regulations and rules in
consultation with your master chimney sweep� For changes after
the printing of this manual, we can not assume any liability� We
reserve the right to change without notice�
Note
The sections for circulating air and supply air, as prescribed in the
“Fachregeln des Ofen- und Luftheizungsbauerhandwerks TR-OL
2006” (rules of the tiled stove and air heating system builder trade)
must be observed�
A supply air section of 200cm2, and a circulating air section of
200cm2 have already been provided in the appliance�