background image

22

6. IMPORTANT INFORMATION

General warning and safety information

Observance of the introductory general warning information is 
imperative.

 

Q

Read the entire manual thoroughly before installing and putting 
the stove into service. Observe the national provisions and laws 
as well as the regulations and rules applicable locally.

 

Q

RIKA stoves should only be installed in rooms with normal humidity 
(dry areas according to VDE 0100 Part 200). The furnaces are not 
splash water protected and may not be installed in wet areas.

 

Q

Only approved transport equipment with sufficient load carrying 
capacity may be used with your heating appliance.

 

Q

Your heating appliance is not suitable for use as a ladder or 
stationary scaffolding.

 

Q

The burning of fuel releases heat energy that lead to extensive 
heating of the stove surfaces, doors, door and operating handles, 
glass, flue pipes and possibly the front wall. Refrain from touching 
these parts without appropriate protective clothing or equipment 
e.g. heat-resistant gloves or means of operation (operating 
handle).

 

Q

Make your children aware of this particular danger and keep 
them away from the stove during heating.

 

Q

Only burn approved heating materials.

 

Q

The combustion or introduction of highly flammable or explosive 
materials such as empty spray cans etc. in the combustion 
chamber and storing them near the stove is strictly prohibited 
due to the danger of explosion.

 

Q

No light or inflammable clothing is to be worn when post-heating.

 

Q

Use the heat-resistant gloves supplied to open the doors of your 
stove.

 

Q

Make sure that no embers fall out of the combustion chamber 
onto inflammable material.

 

Q

Placing non-heat resistant objects on the stove or near it is 
prohibited.

 

Q

Do not place clothing on the stove to dry.

 

Q

Laundry racks etc. must be placed at a sufficient distance to the 
stove – ACUTE DANGER OF FIRE!

 

Q

When your stove is burning, the use of highly inflammable and 
explosive materials in the same or adjacent rooms is prohibited.

 

Q

If the stove is heated in continuous operation, the cleaning 
intervals are shorter. Increased wear, especially of the thermally 
stressed parts, is the result. Please therefore strictly follow the 
requirements for cleaning and maintenance!

Note

Waste and liquids may not be burnt in the stove!

Note

To prevent your stove from overheating of the internal components,
do never cover the convection fins!

Note

 

CAUTION when filling the pellet container. The opening of the pellet 
container is sufficiently dimensioned to ensure easy filling. Take 
great care that no pellets drop to the convection fins and the hot 
stove body. This can cause a lot of smoke. 

Tip

Therefore we recommend refilling the pellet container at a cold 
stove.

Note

Your stove will expand and contract during the heating and cooling 
phase. This can sometimes lead to slight bending or cracking 
noises. This is normal and is no reason for a complaint.

First heating

The stove body, just as various steel parts, cast iron parts and the 
flue pipes are painted with a heat resistant paint. During the first 
heating the paint dries out completely. This may cause a slight smell. 
Touching or cleaning the painted surfaces during the curing should 
be avoided. The hardening of the paint is finished after the first 
heating with high power. 

Safety distances

Note

1. To non-combustible objects
a > 40 cm, b > 10 cm
2. To combustible objects and reinforced concrete load-bearing 
walls
a > 80 cm, b > 10 cm

Tip

Please observe a minimum distance of 20 cm behind and sideways 
the stove for maintenance.

Summary of Contents for DOMO PGI MULTIAIR

Page 1: ...DOMO PGI MULTIAIR Notice de montage...

Page 2: ...n tuyau MULTIAIR de deux m tres en combinaison avec une sortie d air design RIKA les valeurs peuvent diff rer dans la pratique En raison de diff rentes densit s apparentes des pellets la capacit en kg...

Page 3: ...e clapet de nettoyage doit tre pr sente pour une inspection et un nettoyage r guliers Le raccordement au conduit doit tre r alis de fa on tanche Air de combustion Tout processus de combustion a besoin...

Page 4: ...inge s cher sur le po le Q Les s choirs linge ou dispositifs de m me type doivent tre plac s une distance suffisante de l appareil de chauffage RISQUE LEV D INCENDIE Q Lorsque votre appareil de chauff...

Page 5: ...tation en s curit Attention En tant que po le ind pendant de l air ambiant votre po le est contr l selon la norme EN 14785 Il peut tre install en fonctionnement d pendant ou ind pendant de l air LE FO...

Page 6: ...agonale L03372 Cache B17527 Soufflerie de convection 3x N112040 Vis hexagonale 2x N103657 Serre c ble L02724 Cache pour moteur Explication des symboles Information importante 8 Tournevis hexagonal 8 1...

Page 7: ...des autorit s comp tentes l emplacement du raccordement Q La temp rature maximale de l air de convection se monte 180 C la sortie de l appareil Q La conduite d air de convection doit tre la plus cour...

Page 8: ...tir e D vissez les vis marqu es du po le et retirez la t le de protection thermique La t le de protection thermique n est plus n cessaire apr s le d montage et peut tre jet e Retirez la vis aveugle po...

Page 9: ...vue cet effet dans le panneau Fixez ensuite le cache c ble Montez le panneau arri re du po le Le moteur de convection doit tre recouvert par son cache Il s accroche simplement Attention Un fonctionne...

Page 10: ...Gebruikershandleiding DOMO PGI MULTIAIR...

Page 11: ...5 5 Schouwtrek Pa 3 bij MULTIAIR leiding van twee meter in combinatie met RIKA designuitlaat waarden kunnen in de praktijk afwijken Capaciteit in kg kan door verschillende bulkdichtheden van de pellet...

Page 12: ...uik uitsluitend dubbelwandig ge soleerde inox kanalen flexibele aluminium en flexibele staalkanalen zijn niet toegelaten Integreer een reinigingsopening in uw rookgasafvoerkanaal voor een regelmatig o...

Page 13: ...tand van de kachel te worden geplaatst Q Als uw kachel brandt is het gebruik van licht ontvlambare en ontplofbare stoffen in dezelfde of in nabijgelegen ruimtes verboden Q Als de kachel continu werkt...

Page 14: ...Q Door vervuiling van de schoorsteen d w z afzettingen van licht ontvlambaar materiaal zoals roet en teer kan schoorsteenbrand ontstaan Een incorrecte berekening en foutieve afmeting van de schoorstee...

Page 15: ...4x N106472 Duo Taptite L03372 Afdekplaat B17527 Convectieventilator 3x N112040 Duo Taptite 2x N103657 Kabelbinder L02724 Afdekplaat motor Verklaring symbolen belangrijke aanwijzing 8 Zeskant 8 10 13 Z...

Page 16: ...tra ruimte Q Houd rekening met de plaatselijke voorschriften omtrent brandveiligheid Q De maximale temperatuur van de verwarmde lucht op de uitlaat van de kachel is 180 C Q Houd de lengte van het kana...

Page 17: ...erde schroeven van de kachel los en verwijder de hittebeschermingsplaat De hittebeschermingsplaat is na demontage niet meer nodig en kan worden weggegooid Verwijder de blinde schroef aan de onderkant...

Page 18: ...in de opening Aanwijzing De kachel laten functioneren zonder afdekplaat is uit veiligheidsoverwegingen niet toegelaten Een foutieve plaatsing leidt tot verlies van garantie en voor schade wordt er ge...

Page 19: ...Operating manual DOMO PGI MULTIAIR...

Page 20: ...KA design outlet values may differ in practice The capacity in kg may deviate due to different pellet bulk densities The owner of small firing systems or the person authorised for the small firing sys...

Page 21: ...on must be calculated and shown with EN13384 1 and EN13384 2 Use only insulated double stainless steel tubes flexible aluminum or steel tubes are not permitted An inspection door for regular inspectio...

Page 22: ...at resistant objects on the stove or near it is prohibited Q Do not place clothing on the stove to dry Q Laundry racks etc must be placed at a sufficient distance to the stove ACUTE DANGER OF FIRE Q W...

Page 23: ...urs disconnect the mains plug Phone the fire brigade and get yourself and other residents out of harm s way Note Your pellet stove has been tested as a room air independent stove according to EN14785...

Page 24: ...plate 4x N106472 Hex bolt L03372 Cover plate B17527 Convection fan complete 3x N112040 Hex bolt 2x N103657 Cable tie L02724 Motor cover Explanation of symbols Important Information 8 Hex 8 10 13 Hex...

Page 25: ...gional specific fire safety regulations and clarify the connection situation with the competent authority Q The max temperature of the convection air is 180 C at the air outlet Q The convection air du...

Page 26: ...ked screws from the stove and remove the heat protection plate The heat protection plate is no longer needed after disassembly and can be disposed of Remove the blind screw positioned underneath It is...

Page 27: ...that purpose in the rear panel Mount the cable cover Install the rear wall of the stove The fan motor must be covered with the motor cover This is only hanged in Note Operation without a cover is not...

Page 28: ...zoals spelling of drukfouten voorbehouden 2021 RIKA Innovative Ofentechnik GmbH In case of doubt as well as missing or incorrect translations the German version is the only valid one Subject to techn...

Reviews: