Spare part overview - article numbers

Note: Please consider the powdercoated parts can differ slightly in colour and colour effects though they are elaborated in high quality�

Nr.

Art.Nr.

Description

1

B19093

Decorative door assy

2

N111784

Allen screw

3

N110017

Allen screw

4

N112240

Self-tapping screw M05x10

5

Z38729

Washer

6

L03966

Hinge

7

L03962

Hinge plate

8

LB00930

Bottom front panel assy

9

N111990

Hexagon socket

10

Z38980

Mount electromagnet

11

N108830

Fillister head screw

12

Z36171

Electromagnet

13

B17521

Pressure spring

14

N112438

Hexagonal countersunk screw

15

L02714

Magnet washer

16

N108131

Pressure spring

17

L04055

Door stop bottom

18

N112274

Hexagonal nut M05

19

L04056

Door stop top

20

N112190

Hexagon socket screw

21

L02647

Closure plate

22

B17407

Shutter

23

N111956

Grub screw

24

N111965

Washer M05

25

Z14921

Closure plate

26

Z35464

Combustion chamber door black

27

N112551

Round sealing strip grey D11 (1m)

28

N103693

Flat seal black 8x2

29

Z35856

Front door glass

30

B17524

Hinge black

31

B17405

Hinge

32

N111780

Hexagonal nut

33

N112201

Hexagon socket screw

34

L00475

Glass holder

35

B15825

Hinge BA1

36

N111950

Hexagonal screw M05x10

37

L02645

Door stop base plate

38

N112551

Round sealing strip grey D11 (1m)

39

Z35465

Front door black assy

40

N112140

Hexagonal screw

50

N112047

Hexagon socket screw M08x35

51

N105049

Flat washer black

52

Z36921

Cleaning opening

53

Z38166

Firebrick lining left

54

Z38171

Baffle plate left

55

Z38170

Firebrick lining front

56

Z38370

Firebrick lining cover

57

Z38168

Firebrick lining cover right

58

Z38169

Firebrick lining rear

59

Z38172

Baffle plate right

60

Z38134

Cast rear panel black

61

Z38167

Firebrick lining right

Nr.

Art.Nr.

Description

62

N112707

Allen screw

63

Z38131

Fire trough

64

N111631

Round sealing cord grey D06

65

Z38132

Turning grid

66

L02726

Small plate

67

N112415

Hexagonal screw

68

L01875

Driving plate turning grid

69

N108131

Pressure spring

70

L03781

Small plate

71

Z35854

Intermediate shaft turning grid

72

N112470

Spring clip

73

Z36167

Ceramic seal

74

Z35851

Bearing plate

75

N108485

Allen screw

76

N102688

Sinter bearing ID16

77

L02642

Bearing holder plate

78

N112160

Self-tapping screw

79

N112499

Setscrew with pin

80

N112125

Circlips

81

Z38161

Drive shaft

82

N112077

Wing nut

83

Z36000

Cleaning cover

84

Z36566

Sealing

85

Z35999

Cleaning cover

86

Z36567

Sealing

87

L03782

Ash drawer

88

Z37830

Pipe adapter seal

89

Z37609

Flue pipe attachments

90

Z38728

Seal

91

Z38979

Cleaning opening

92

N108313

Self-tapping screw

100

Z36921

Cleaning opening

101

N112387

Wing nut

102

N111843

Washer M08

103

N112386

Swing bolt

104

N112390

Cylindrical pin

105

N112551

Round sealing strip grey D11 (1m)

106

Z38133

Combustion chamber lid

107

Z36922

Holder plate

108

N111964

Hexagonal screw

109

N107048

Sealing cord black D10

110

N112696

Hexagonal nut

111

B18133

Hinge

112

N112428

Headless screw

113

N112427

Headless screw

120

N112143

Hexagonal nut M03

121

N112144

Washer M03

122

Z36111

Cover

123

LB00964

Container lid F22

B19219

Container lid assy F22

124

N112142

Flange nut

125

LB00931

Cover display case F22

Summary of Contents for CONNECT PELLET F22

Page 1: ...CONNECT PELLET F22 F38 Operating manual...

Page 2: ...es 16 Prior to set up 17 The correct chimney connection 17 Convection air conduction 17 6 BRIEF INFORMATION ON FUEL PELLETS 18 What are pellets 18 Wood pellet specification according to ENplus A1 18 P...

Page 3: ...the ash drawer 25 Cleaning the door glass 25 Cleaning painted surfaces 25 11 CLEANING 26 Cleaning the convection air openings 26 Combustion air intake 26 Cleaning the pellet container 26 Cleaning the...

Page 4: ...uction systems can interfere with the combustion air supply The flue gas values of the appliance must be observed for the chimney dimensioning Auxiliary electricity consumption At nominal heat output...

Page 5: ...021 In case of doubt as well as missing or incorrect translations the German version is the only valid one Subject to technical and visual changes as well as layout and printing errors 2021 RIKA Innov...

Page 6: ...92 88 89 92 81 79 90 106 111 110 100 105 113 112 109 110 103 104 107 108 102 101 1 19 11 17 11 11 18 18 15 14 16 26 28 29 30 30 34 33 27 22 23 21 20 25 24 20 31 32 35 37 36 32 39 38 30 30 22 23 21 20...

Page 7: ...20 140 136 127 127 127 139 126 135 138 141 135 142 142 154 153 153 127 127 148 147 150 150 145 148 147 146 145 148 147 152 151 149 149 149 137 133 134 134 125 124 124 175 172 170 170 169 169 174 173 1...

Page 8: ...226 225 224 223 226 225 230 229 222 222 222 208 208 205 231 207 212 220 233 232 207 207 193 193 196 195 195 192 190 198 199 209 191 194 207 207 207 211 206 197 195 213 252 249 248 248 247 247 251 250...

Page 9: ...8 271 297 296 300 299 303 304 305 302 302 301 301 312 308 309 310 311 316 313 314 314 315 307 306 260 262 261 267 266 265 263 264 268 286 283 293 291 292 280 291 282 271 281 282 271 279 290 289 284 28...

Page 10: ...MULTIAIR Flue pipe connection top RAO 320 325 323 322 321 323 322 324 333 332 330 331 335 334...

Page 11: ...plate left 55 Z38170 Firebrick lining front 56 Z38370 Firebrick lining cover 57 Z38168 Firebrick lining cover right 58 Z38169 Firebrick lining rear 59 Z38172 Baffle plate right 60 Z38134 Cast rear pa...

Page 12: ...seal Nr Art Nr Description 192 LB00965 Container lid F38 B19220 Container lid assy F38 193 L04058 Rear wall right F22 F38 194 LB00933 Cover display case F38 195 N112142 Flange nut 196 L03975 Small pl...

Page 13: ...y 284 N112378 Hexagon socket screw 285 N112487 Washer 286 L02643 Motor plate 287 Z18105 Hose 289 N106472 Self tapping screw M05x10 290 L03902 Mount 291 N111806 Hexagonal screw 292 N101570 Hexagonal sc...

Page 14: ...ith RIKA design outlet values may differ in practice The capacity in kg may deviate due to different pellet bulk densities The owner of small firing systems or the person authorised for the small firi...

Page 15: ...on must be calculated and shown with EN13384 1 and EN13384 2 Use only insulated double stainless steel tubes flexible aluminum or steel tubes are not permitted An inspection door for regular inspectio...

Page 16: ...nt objects on the stove or near it is prohibited Q Do not place clothing on the stove to dry Q Laundry racks etc must be placed at a sufficient distance to the stove ACUTE DANGER OF FIRE Q When your s...

Page 17: ...is not in operation Q Foulingofthechimneyi e depositsofhighlyinflammablematerials such as soot and tar and subsequently fire in the chimney may occur if the chimney is miscalculated and dimensioned wr...

Page 18: ...ucting measurements with a lignotester internal control Your pellet stove is only approved for the burning of pellets of tested quality Please ask your pellet stove dealer for tested fuel and a list o...

Page 19: ...ng the operational safety The status indicator CLEAN appears on the display Only for stoves with turning grids Every 6 hours interval adjustable an additionally automatic big cleaning cycle is perform...

Page 20: ...8 ASSEMBLY RIKA MULTIAIR Scope of Delivery E15633 B17527 Convection fan complete 3x N112040 Duo Taptite L02724 Motor cover...

Page 21: ...Only work on the unit when the mains plug has been disconnected and the stove has cooled down completely Note During assembly dismantling do not allow objects screws etc to fall into the pellet conta...

Page 22: ...hexagonal screws on the rear panel The rear panel tilts backwards Disconnect the earthing cable You can then lift it upwards Run the MULTIAIR fan cable vertically downwards and then further along the...

Page 23: ...a motor cover and without air duct is not allowed for security reasons Disregard voids your warranty and no liability is accepted for damage Function test and settings Connect the power cord back in a...

Page 24: ...the heating times set at the stove can also be activated You can see whether the external demand is currently activated in the INFO main menu in submenu item Info inputs If your stove receives an ext...

Page 25: ...the grid vertical Remove the clinker using the brush supplied and sweep the ashes with a broom in the ash tray Vacuum out the fire trough Do not damage the ignition when cleaning with the brush Vacuu...

Page 26: ...dour Note To prevent your stove from overheating of the internal components do never cover the convection fins Combustion air intake Note Only when the stove is cold You could vacuum out embers FIRE R...

Page 27: ...screw the two wing screws under the ash door and remove the outer cleaning lid Vacuum the combustion residues off the flue gas collecting duct especially the areas to the side flues Unscrew the 2 wing...

Page 28: ...G MAINTENANCE Problem 2 Stove smells strongly and smokes outside Cause s Q Burning in phase taking into service Q Stove has accumulated dust and or dirt Possible solutions Q Wait to end of burning in...

Page 29: ...ions These are the basic stove functions that are to be checked and ticked off The stove is ready for operation if these functions are ensured Operator instruction This is one of the most important po...

Page 30: ...eight Room ventilation Exhaust hood outdoor connection WC extraction Comments Central vacuum cleaning system YES NO YES NO YES NO YES NO Chimney draft full load Outside temperature Plaster openings YE...

Page 31: ...ified for that type of stove The installation is performed by a RIKA certified technician If these points are not complied with the guarantee claim is void Any costs incurred by the manufacturer as a...

Page 32: ...eramic pane using a suitable tool Remove the seals and separate them from the frame if present Transparent glass ceramic can generally be recycled but must be separated into decorated and non decorate...

Page 33: ...EN 33 32...

Page 34: ......

Page 35: ...EN 35 34...

Page 36: ...valid one Subject to technical and visual changes as well as layout and printing errors 2021 RIKA Innovative Ofentechnik GmbH Z39059_CONNECT_PELLET_EN 7 12 2021 RIKA Innovative Ofentechnik GmbH M lle...

Reviews: