RIGOL
Command Systems
Programming Guide for DS1000E, DS1000D Series
2-38
3.
:TRIGger:DURation:QUALifier
Command Format:
:TRIGger:DURation:QUALifier
<qual>
:TRIGger:DURation:QUALifier?
Function Explanation:
;
The commands set and query the limiting condition of trigger time. <qual>
could be GREaterthan, LESSthan or EQUal.
Returned Format:
The query returns GREATER THAN, LESS THAN or EQUAL.
Example:
:TRIG:DUR:QUAL GRE Setup the limiting condition as “GREaterthan”.
:TRIG:DUR:QUAL?
The query returns GREATER THAN.