RIGOL
DP1116A Performance Verification Manual
7
Voltage Programming Control Speed (1% within the total variation range)
Rise
Full Load 50 ms
No Load
20 ms
Fall
Full Load 45 ms
No Load
400 ms
OVP/OCP
Accuracy ±(Output
PerOffset)
0.5% + 0.5 V/0.5% + 0.5 A
Activation Time
1.5 ms (OVP ≥ 3 V); < 10 ms (OVP < 3 V)
< 10 ms (OCP)
Mechanical
Dimensions
235 mm(W) x 155 mm(H) x 384 mm(D)
Weight
11 kg
Power
AC Input
(50Hz to 60Hz)
100 Vac ± 10%, 115 Vac ± 10%
220 Vac ± 10%, 230 Vac ± 10%
Environment
Working Temperature
Full Rated Value Output: 0
℃
to 40
℃
Under Relatively Higher Temperature: the linearity of the output
current reduces to 50% at the highest temperature 55
℃
Cooling Method
Fan Cooling
Conformity
CE, cTUVus
Note
[1]
: The accuracy parameters are acquired via calibration under 25
℃
after 1-hour warm-up.
Note
[2]
: The maximum time required for the output to change accordingly after receiving the APPLy and SOURce
commands.
Note
[3]
: The variation of the output within 8 hours after 30-minute warm-up when the load circuit and environment
temperature are constant.