Chapter 2 Front Panel Operations
RIGOL
DG1000Z User’s Guide
2-31
To Set Fundamental Waveform Parameters
DG1000Z allows users to set various fundamental waveform parameters such as
frequency, period, amplitude, DC offset voltage, high level, low level and start phase.
It also supports align phase operation. Please refer to introductions in “To Output
Basic Waveform” to set above fundamental waveform parameters.
To Set Harmonic Order
The highest order of harmonic output from DG1000Z can not be greater than this
setting value.
After entering the harmonic setting menu, press Order (at this point, “Order” on the
screen is highlighted) and use the numeric keyboard or knob to input the desired
harmonic order.
The range is limited by the maximum output frequency of the instrument and
current fundamental waveform frequency.
Range: 2 to maximum output frequency of the instrument÷current
fundamental waveform frequency (must be integer).
The maximum is 8.
To Select Harmonic Type
DG1000Z can output even harmonic, odd harmonic, all orders of harmonic and
user-defined orders of harmonic. After entering the harmonic setting menu, press
Type to select the desired harmonic type.
1.
Even
Press this key and the instrument will output fundamental waveform and even
harmonics.
2.
Odd
Press this key and the instrument would output fundamental waveform and odd
harmonics.
3.
All
Press this key and the instrument would output fundamental waveform and all
the harmonics in order.
4.
User
Press this key and the instrument would output the user-defined orders of
harmonics. The highest order is 8.
Summary of Contents for DG1022Z
Page 2: ......
Page 12: ...RIGOL X DG1000Z User s Guide...
Page 38: ......
Page 54: ...RIGOL Chapter 2 Front Panel Operations 2 16 DG1000Z User s Guide Figure 2 3 Sine Waveform...
Page 154: ......
Page 157: ...Chapter 3 Remote Control RIGOL DG1000Z User s Guide 3 3 7 5 6...
Page 164: ......
Page 174: ......