Chapter 2 Front Panel Operations
RIGOL
DG1000Z User’s Guide
2-9
Align Phase
DG1000Z series dual-channel generators enable to align the phases of the two
channels. Pressing down this softkey will re-configure the two channels and enable
the generator to output with specified frequency and start phase.
For two signals whose frequencies are the same or in multiple, this operation will
align their phases. For example, assume a sine waveform (1kHz, 5Vpp, 0°) is
outputed from CH1, while another one (1kHz, 5Vpp, 180°) from CH2. Use an
oscilloscope to sample and display the two signals, you will see that the waveforms
shown on the oscilloscope do not always have a phase deviation of 180°. At this
point, press Align Phase on the generator and the waveforms shown on the
oscilloscope will have a phase deviation of 180° without any adjustment of the start
phase of the generator.
Figure 2-1 Before Aligning Phase
Figure 2-2 After Aligning Phase
KET POINTS:
The Align Phase menu is grayed out and disabled when any one of the two
channels is in modulation mode.
CH1
CH2
CH1
CH2
Summary of Contents for DG1022Z
Page 2: ......
Page 12: ...RIGOL X DG1000Z User s Guide...
Page 38: ......
Page 54: ...RIGOL Chapter 2 Front Panel Operations 2 16 DG1000Z User s Guide Figure 2 3 Sine Waveform...
Page 154: ......
Page 157: ...Chapter 3 Remote Control RIGOL DG1000Z User s Guide 3 3 7 5 6...
Page 164: ......
Page 174: ......