background image

 

5

4

1.0µL        1.5µL              2.0µL             3.0µL            4.0µL

- Before using the 

Rightest

to test your blood glucose, please read all the 

instructions and practice the tests including quality control test ( Refer to page 35 ).

- Please do the quality control test regularly to make sure the test results are accurate.
- The 

Rightest

Blood Glucose Meter can only be used with the 

Rightest

Blood Glucose Test Strips. 

The use of any other brand Strips should not be used under any circumstances. The use of other brands of strips may 
give inaccurate results.

- The 

Rightest

Blood Glucose Monitoring System is intended for 

in vitro

 diagnostic use only. The testing result 

is calibrated to be the plasma equivalent for tests with fresh capillary whole blood samples from the fingertip, palm and 
forearm.

-  The 

Rightest

Blood  Glucose  Monitoring  System  is  intended  for  self-testing.  It  should  not  be  used  to 

diagnose diabetes mellitus.

Rightest

Blood Glucose Monitoring System has not been validated for use on neonates. Therefore, it's not 

intended for use of neonates.

Rightest

Blood  Glucose  Monitoring  System  has  not  been  used  for  arterial  blood  testing,  so  it  is  still  not 

suitable to be used for arterial blood testing.

- Perform the test at least 30 minutes after while entering another site with different ambient temperature.
- Pay attention to the environment protection when disposing of the batteries.

® 

GM250S

 

Blood Glucose Monitoring System 

®

®

 

GM250S

 

 

GS250S 

® 

GM250S

 

® 

GM250S

 

® 

GM250S

 

® 

GM250S

 

Precaution

Precaution

Please take a minimum of 1.0µL to perform the test on 

Rightest

Glucose Monitoring System. Blood 

sample size above 3.0µL might contaminate the test strip port and the meter.
Blood sample size below 1.0µL might cause inaccurate test result or might not start the meter measurement. In this case, 
repeat the test with a new test strip.

® 

GM250S

 

Blood 

PRECAUTOIN

The 

Rightest

 Glucose Meter will be set to mg/dL by default when sold in the United States. 

When your display shows " mmol/L " during setting or test, please contact customer service. Use of the wrong unit 
of measure may result in incorrect treatment.  

® 

Gm250S

 

Blood

Sample Size Example

- Do not expose to dripping or splashing.
- The minimum blood sample size of 

Rightest

 Glucose Monitoring System is 1.0µL:(    ) 

® 

GM250S

 

Blood

Summary of Contents for GM250S

Page 1: ......

Page 2: ...stem which provides considerate design and accurate results your diabetes management can become more reliable and ease to use The GM250S Blood Glucose Monitoring System is intended for in vitro diagno...

Page 3: ...onates Rightest Blood Glucose Monitoring System has not been used for arterial blood testing so it is still not suitable to be used for arterial blood testing Perform the test at least 30 minutes afte...

Page 4: ...omponents Parts Log Book Warranty Card Emergency Card 35 37 39 42 43 47 48 50 51 52 53 54 76 79 About Rightest System The Rightest Blood Glucose Monitoring System GM250S The Rightest GM250S Blood Gluc...

Page 5: ...Strip Package Insert 4 Control Solution Package Insert 5 GM250S Blood Glucose Meter with 1 CR2032 battery installed GS250S 6 Blood Glucose Test strips 0 10 25 pcs 7 Control Solution 8 Lancing Device 9...

Page 6: ...ative information Test Strip Port Insert test strip here until you hear a click Product name Meter Serial Number Meter Battery Left Button For operating the meter please check details in following sec...

Page 7: ...n the battery is low when the battery is dead Instruction to apply your blood sample Appears after you insert test strip into meter Appears when you use an invalid strip Current date under Time mode T...

Page 8: ...ng signal output terminals PRECAUTION Re cap the Rightest GS250S Blood Glucose Test Strip vial immediately after taking out a test strip Do not reuse Rightest GS250S Blood Glucose Test Strip Do not us...

Page 9: ...ollow the local regulation and discard a used battery properly 4 The Rightest GM250S Blood Glucose Meter performs a self test 5 Press any button to exit the self test and enter Setting Mode 6 Set the...

Page 10: ...l do self test Press the main button to exit the self test and enter Setting Mode 2 Press the Main button Press the main button to turn on the Rightest GM250S Blood Glucose Meter Then press and hold t...

Page 11: ...eep 5 Hour setting With the hour blinking press the Left or Right button until the current hour appears Then press the Main button to confirm it and move to minute setting 6 Minute setting With the mi...

Page 12: ...automatically if you don t operate it for over 2 minutes Handling the GS250S Test Strip Rightest How to easily handle the Rightest GS250S Blood Glucose Test Strip Inserting the Rightest GS250S Blood...

Page 13: ...e it easier to remove it from the meter 3 Take the Rightest GS250S Blood Glucose Test Strip completely out of test strip port Please follow the local regulation and discard used strips properly Before...

Page 14: ...re based on skin type for soft or thin skin for average skin for thick or calloused skin 7 Hold the hub in one hand and pull on the plunger in the other hand The device will be cocked Release the plun...

Page 15: ...rming a Blood Test 13 Touch and hold the drop to the edge of sample entry until you hear a beep if volume is turned on and the View Window is totally filled with blood If the View Window is not totall...

Page 16: ...ng device for palm or forearm the blood sample might be not enough for the meter Please periodically compare the test system to a laboratory test system known to be well maintained and monitored by a...

Page 17: ...test at least 30 minutes after entering another location with different ambient temperature Blood glucose test results are shown on the Rightest GM250S Blood Glucose Meter as mg dL If your blood gluco...

Page 18: ...trol Solution Range printed on the strip vial label the Rightest GM250S Blood Glucose Monitoring System passes the Quality Control Test That means your Rightest GM250S Blood Glucose Monitoring System...

Page 19: ...Control Solutions please contact your authorized Bionime representative Rightest PRECAUTION Each time you open a new bottle of Control Solution is good for 3 months after opening the bottle or until...

Page 20: ...ain button again and you will enter the Average screen By pressing the Right button the display shows AVG on the upper right corner of the display and the average value for the actual day By sequentia...

Page 21: ...earching the tests the latest value to the oldest one by using the Left button you can scroll from the oldest to the latest one Anytime you want to stop just release the pressed button It will stop an...

Page 22: ...ter or any other liquid Store the meter in the carrying case when not in use If meter is dropped or damaged perform a quality control test with the control solution before doing a blood glucose test C...

Page 23: ...t the test result is only for reference because the test result under these ranges of temperature might not be correct In the memory screen this value will be flagged with symbol 1b Repeat the test at...

Page 24: ...ips are designed for use with capillary whole blood samples Do not use serum or plasma samples Inaccurate test results may be obtained at high altitude more than about 10000 feet 3048 meters above sea...

Page 25: ...se Electrochemical Sensor Plasma Capillary whole blood Operating Temperature Operating Relative Humidity Power Saving 500 blood glucose test results with date and time Hematocrit Power Supply Meter Ba...

Page 26: ...Bionime Corporation warrants that your Rightest Blood Glucose Meter will be free from defects in materials and workmanship for five years from the date of purchase This warranty does not apply to the...

Page 27: ...can Association for Clinical Chemistry AACC Electronic Version Retrieved June 15 2010 from www labtestsonline org understanding analytes glucose test html Rightest Blood Glucose Meter GM250 Test Strip...

Page 28: ...ion Blood Glucose Insulin Medication Blood Glucose Insulin Medication Blood Glucose Insulin Medication Blood Glucose Insulin Medication Name Address Home Phone Doctor Pharmacy Insulin Pills In case of...

Page 29: ...Glucose Insulin Medication Blood Glucose Insulin Medication Blood Glucose Insulin Medication Log Book Log Book Breakfast Lunch Dinner Bedtime Other Comments DATE M T W T F S S Blood Glucose Insulin M...

Page 30: ...Glucose Insulin Medication Blood Glucose Insulin Medication Blood Glucose Insulin Medication Log Book Log Book Breakfast Lunch Dinner Bedtime Other Comments DATE M T W T F S S Blood Glucose Insulin M...

Page 31: ...Glucose Insulin Medication Blood Glucose Insulin Medication Blood Glucose Insulin Medication Log Book Log Book Breakfast Lunch Dinner Bedtime Other Comments DATE M T W T F S S Blood Glucose Insulin M...

Page 32: ...Glucose Insulin Medication Blood Glucose Insulin Medication Blood Glucose Insulin Medication Log Book Log Book Breakfast Lunch Dinner Bedtime Other Comments DATE M T W T F S S Blood Glucose Insulin M...

Page 33: ...Glucose Insulin Medication Blood Glucose Insulin Medication Blood Glucose Insulin Medication Log Book Log Book Breakfast Lunch Dinner Bedtime Other Comments DATE M T W T F S S Blood Glucose Insulin M...

Page 34: ...Glucose Insulin Medication Blood Glucose Insulin Medication Blood Glucose Insulin Medication Log Book Log Book Breakfast Lunch Dinner Bedtime Other Comments DATE M T W T F S S Blood Glucose Insulin M...

Page 35: ...Glucose Insulin Medication Blood Glucose Insulin Medication Blood Glucose Insulin Medication Log Book Log Book Breakfast Lunch Dinner Bedtime Other Comments DATE M T W T F S S Blood Glucose Insulin M...

Page 36: ...Glucose Insulin Medication Blood Glucose Insulin Medication Blood Glucose Insulin Medication Log Book Log Book Breakfast Lunch Dinner Bedtime Other Comments DATE M T W T F S S Blood Glucose Insulin M...

Page 37: ...Glucose Insulin Medication Blood Glucose Insulin Medication Blood Glucose Insulin Medication Log Book Log Book Breakfast Lunch Dinner Bedtime Other Comments DATE M T W T F S S Blood Glucose Insulin M...

Page 38: ...Glucose Insulin Medication Blood Glucose Insulin Medication Blood Glucose Insulin Medication Log Book Log Book Breakfast Lunch Dinner Bedtime Other Comments DATE M T W T F S S Blood Glucose Insulin M...

Page 39: ...ot Rightest Test Strips manufactured by Bionime Use only Rightest Blood Glucose Test Strips in your Rightest Blood Glucose Meter 3 The sole obligation of Bionime under this warranty shall be to replac...

Page 40: ...insulin Yes No Oral medication Yes No How did you hear about the Rightest Blood Glucose Monitoring System GM250S GM250S Thank you for purchasing our product Please complete and mail this warranty card...

Reviews: