20138630
42
GB
Operation, indications, diagnostic
8.3.2
Before starting with a new program module or
when the program module is replaced
Tab. AB
The display shows
rSt
and
PrC
alternately.
The display shows the replacement of the program module.
The indicator light blinks alternately one red and two yellow.
Press
for >3 to start the download of the program module data.
The indicator light blinks yellow.
The process that lasts 3 seconds is accompanied by short yellow blinking.
Note:
If you press
for <3 seconds, the download does not start. To restart the reset process, you need
to reset the LME7... switching the mains ON/OFF.
The display shows 'run' during the download (reset process) of the program sequence.
The display shows rSt and End alternately.
The display shows the end of the data exchange.
After 2 minutes, the unit passes to
Loc 138
At the end of the reset process, the unit is automatically in a lockout position (LOC 138) and need to
be released in order to work!
Press
for >1 second to release the unit.
Display:
OFF
Alternatively
nfo
> 3s
nfo
nfo
Alternatively
Alternatively
nfo
> 1s
nfo
WARNING
At the first start-up or after replacing the pro-
gram module, after the completion of the re-
store process the sequence of the functions
and the parameter settings should be
checked.
WARNING
Replacing the program module will result in
the loss of any settings made previously on
the control box.