Technical description of the burner
3.7
Firing rates
The burners can operate in two modes: one-stage or two-stage.
The
MAXIMUM OUTPUT
is selected from within area A (Fig. 2).
The
MINIMUM OUTPUT
must not be lower than the minimum
limit of the diagram:
RS 150 = 300 kW
3.8
Test boiler
The firing rates were set in relation to special test boilers, accord-
ing to EN 676 regulations.
In Fig. 3 you can see the diameter and length of the test combus-
tion chamber.
Example:
Output 756 kW: diameter = 60 cm; length = 2 m.
WARNING
The firing rate value (Fig. 2) has been obtained
considering an ambient temperature of 20 °C, an
atmospheric pressure of 1013 mbar (approx. 0 m
a.s.l.), and with the combustion head adjusted as
shown on page 18.
Pressur
e
in
combu
stio
n chamber -
mba
r
Thermal power -
kW
Fig. 2