Safety

Please read and keep in a safe place

 Please read through these instructions 

carefully before installing or operating. Following the 
installation, pass the instructions on to the opera-
tor. This unit must be installed and commissioned 
in accordance with the regulations and standards 
in force. These  instructions can also be found at 
www.docuthek.com.

Explanation of symbols
 • ,   ,   ,   

... = Action

 

= Instruction

Liability

We will not be held liable for damage resulting from 
non-observance of the instructions and non-com-
pliant use.

Safety instructions

Information that is relevant for safety is indicated in 
the instructions as follows:

 DANGER

Indicates potentially fatal situations.

 WARNING

Indicates possible danger to life and limb.

 CAUTION

Indicates possible material damage.

All interventions may only be carried out by qualified 
gas technicians. Electrical interventions may only be 
carried out by qualified electricians.

Conversion, spare parts

All technical changes are prohibited. Only use OEM 
spare parts.

Changes to edition 07.7

The following chapters have been changed:
–  Checking the usage
– Wiring
– Maintenance

Contents

Operating instructions

D

GB

F

NL

I

E

GB-1

0554

Translation from the German

Gas pilots ZMI, ZMIC

Gas pilots ZMI, ZMIC . . . . . . . . . . . . . . . . . . . . 
Contents  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 
Safety. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 
Checking the usage . . . . . . . . . . . . . . . . . . . . . 
Checking the gas type. . . . . . . . . . . . . . . . . . . 
Installation  . . . . . . . . . . . . . . . . . . . . . . . . . . . . 

ZMIC  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
ZMIC..K  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4

Wiring  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Leak test . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Commissioning. . . . . . . . . . . . . . . . . . . . . . . . . 5

ZMI. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
ZMIC  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5

Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . 5

Replacing the electrode . . . . . . . . . . . . . . . . . . . 5

ZMIC..K: replacing the bellows unit  . . . . . . . . . . 6
ZMIC: replacing the ceramic tube. . . . . . . . . . . . 6

Accessories  . . . . . . . . . . . . . . . . . . . . . . . . . . . 7

Technical data  . . . . . . . . . . . . . . . . . . . . . . . . . 7

Logistics  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Declaration of Incorporation. . . . . . . . . . . . . . 8
Certification  . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Contact  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0

Safety

Contents

Summary of Contents for ZMI

Page 1: ...atal situations WARNING Indicates possible danger to life and limb CAUTION Indicates possible material damage All interventions may only be carried out by qualified gas technicians Electrical interven...

Page 2: ...ner bracket 6 Flame tube 7 Enclosed documentation operating instructions and flow rate curves Burner size gas type rated capacity Pmax flame tube length connection see type label D 49018 Osnabr ck Ger...

Page 3: ...ressures can be adjusted ZMI Recommended inlet pressures gas up to 80 mbar up to 32 WC air up to 120 mbar up to 47 WC 1 3 2 Remove the transport safety device Burner Size 16 25 ZMI G G1 ZMI T NPT 1 NP...

Page 4: ...rom the power supply For the ionization and ignition cables use un screened high voltage cable FZLSi 1 7 50 to 180 C 58 to 356 F Order No 04250410 or FZLK 1 7 5 to 80 C 23 to 176 F Order No 04250409 W...

Page 5: ...being formed in the furnace chamber An incorrect change of the burner settings may change the gas air ratio and lead to unsafe operating conditions CO is odourless and poisonous 5 Set the pressure reg...

Page 6: ...ZMI 16G 25 mm Burner L2 ZMI 25B 35 mm ZMI 25D 20 mm ZMI 25G 35 mm L2 ZMIC Reconnect the terminal boot Produce a maintenance report ZMIC K replacing the bellows unit 4 3 2 1 Make a mark to show the len...

Page 7: ...sure 15 to 90 mbar 6 to 35 WC each depending on the gas type burner pressures see www docuthek com Type of document Flow rate curve Burner length increments 100 mm 4 Gas types natural gas LPG gaseous...

Page 8: ...cle 1 1 3 1 1 5 1 3 2 1 3 4 1 5 2 1 7 4 1 5 10 Folgende harmonisierte Normen wurden angewandt The following harmonized standards have been applied Lotte B ren Matthias Rieken Sebastian Escher Datum Da...

Page 9: ...GB 9 D GB Certification Eurasian Customs Union The product ZMI ZMIC meets the technical specifi cations of the Eurasian Customs Union...

Reviews: