42
Operating
line
User level Function
Default value
Min
Max
Unit
3561
O
Return setpoint min OEM
8
8
95
°C
3562 O
Return influence consumers
Off ¦ On
On
3570
O
Actuator running time
120
30
873
s
3571
O
Mixing valve Xp
32
1
100
°C
3572
O
Mixing valve Tn
120
10
873
s
3590
O
Temp differential min
− − −
− − − / 0
20
°C
Solar
3810
F
Temp diff on
8
0
40
°C
3811
F
Temp diff off
4
0
40
°C
3812
F
Charg temp min DHW st tank
− − −
− − − / 8
95
°C
3813
O
Temp diff on buffer
− − −
− − − / 0
40
°C
3814
O
Temp diff off buffer
− − −
− − − / 0
40
°C
3815
F
Charging temp min buffer
− − −
− − − / 8
95
°C
3816
O
Temp diff on swi pool
− − −
− − − / 0
40
°C
3817
O
Temp diff off swi pool
− − −
− − − / 0
40
°C
3818
F
Charging temp min swi pool
− − −
− − − / 8
95
°C
3822 F
Charging prio storage tank
None ¦ DHW storage tank ¦ Buffer
DHW storage tank
3825
F
Charging time relative prio
− − −
− − − / 2
60
min
3826
F
Waiting time relative prio
5
1
40
min
3827
F
Waiting time parallel op
− − −
− − − / 0
40
min
3828
F
Delay secondary pump
60
0
600
s
3830
O
Collector start function
− − −
− − − / 5
60
min
3831
F
Min run time collector pump
20
5
120
s
3832
O
Collector start function on
07:00
00:00
23:50
hh:mm
3833
O
Collector start function off
19:00
00:00
23:50
hh:mm
3834
F
Collector start funct gradient
− − −
− − − / 1
20
min/°C
3840
F
Collector frost protection
− − −
− − − /
-20
5 °C
3850
F
Collector overtemp prot
− − −
− − − /
30
350 °C
3860
F
Evaporation heat carrier
− − −
− − − /
60
350 °C
3870 (***) F
Pump speed min
40
0
100
%
3871 (***) F
Pump speed max
100
0
100
%
3872 (***) O
Speed Xp
32
1
100
°C
3873 (***) O
Speed Tn
120
10
873
s
3880 F
Antifreeze
None ¦ Ethylen glycol ¦ ¦ Propylene glycol
¦ Etyl and propyl glycol
None
3881 F
Antifreeze
concentration
30
1 100 %
3884 F
Pump
capacity
200
10 1500 l/h
Solid fuel boiler
4102 F
Locking other heat sources
Off ¦ On
On
4110 F
Setpoint
min
40
8 120 °C
4130
F
Temp diff on
8
1
40
°C
4131
F
Temp diff off
4
0
40
°C
4133 F
Comparative temp DHW
sensor B3 ¦ DHW sensor B31 ¦ Buff st
tank sensor B4 ¦ Buff st tank sensor B41 ¦
Flow temp setpoint ¦ Setpoin min
Setpoint min
E
=End user
I
=Commissioning
F
=Heating engineer
O
=OEM
BZ
=Operating line
(*) QAA75../78.. only, (**) RIELLOtech CLIMA COMFORT only, (***) RIELLOtech CLIMA TOP only.