20140894
30
GB
Electrical system
6.2.5
Calibration of thermal cutout
This is required to avoid motor burn-out in the event of a signifi-
cant increase in power absorption caused by a missing phase.
6.2.6
Electrical cable fastening
Use flexible cables according to EN 60 335-1. Regulations:
–
if in PVC sheath, use at least H05 VV-F;
–
if in rubber sheath, use at least H05 RR-F.
All cables to be connected to the burner terminal strip 6) (Fig. 7
on page 13) should pass through fairleads 7) (Fig. 7 on page 13).
The fairleads and precut holes can be used in various ways. One
example is given below:
The PRESS GW Model (Fig. 29)
1 - Single-phase power supply....................................... Pg 13.5
2 - Control devices TL .................................................... Pg 13.5
3 - Control devices TR ................................................... Pg 13.5
4 - Spare fairlead............................................................ Pg 13.5
5 - Fitting hole for fairlead, if required ............................... Pg 21
6 - Fitting hole for fairlead, if required ............................... Pg 11
7 - Fitting hole for fairlead, if required ............................... Pg 11
The PRESS 1G - 2G - 3G Models (Fig. 29)
1 - Three-phase power supply .......................................... Pg 21
2 - Single-phase power supply....................................... Pg 13.5
3 - Control devices TL .................................................... Pg 13.5
4 - Control devices TR ................................................... Pg 13.5
5 - Spare fairlead............................................................ Pg 13.5
6 - Fitting hole for fairlead, if required ............................... Pg 11
7 - Fitting hole for fairlead, if required ............................... Pg 11
8 - Fitting hole for fairlead, if required ............................... Pg 11
To ensure that the IP 40 protection classification is maintained,
close all unused fairlead fitting holes.
WARNING
do not invert the neutral with the phase wire in the
electricity supply line.
1
2
3
MAN
AUT
O
STOP
NO
98
97
96
95
RESET
NC
4
TEST/TRIP
Fig. 28
D8685
Fig. 29
D343
PRESS GW
PRESS 1-2-3
Summary of Contents for PRESS 1G