background image

AS 2658:2008

Cert. GSCS20069

SAI Global

AS 2658:2008

Cert. GSCS20054

SAI Global

AS 2658:2008

Cert. GSCS20055

SAI Global

AS 2658 1988

Cert. GSCS20063

SAI Global

AS 2658 2008

Cert. GSCS20063

SAI Global

AS 2658 2008

Cert. GSCS20108

SAI Global

AS 2658 2008

Cert. GSCS20148

SAI Global

AS 2658 2008

Cert. GSCS20148

SAI Global

AS 4551-2008

Cert. GSCS20131

SAI Global

Part No.  RB10, RB20, RB30, 

RB40, RB50

NOTE

Requires LP Gas 2.75kPa regulator and  

hose assembly (not supplied) 

IMPORTANT

Read these instructions for use carefully. 

Familiarise yourself with the appliance  

before connecting it to it’s gas container. 

Keep these instructions for future reference.

CAST IRON

 RING BURNERS

Instruction Manual

companionleisure.com.au

Summary of Contents for RB10

Page 1: ...RB20 RB30 RB40 RB50 NOTE Requires LP Gas 2 75kPa regulator and hose assembly not supplied IMPORTANT Read these instructions for use carefully Familiarise yourself with the appliance before connecting it to it s gas container Keep these instructions for future reference CAST IRON RING BURNERS Instruction Manual companionleisure com au ...

Page 2: ...ion please take care when handling or moving the appliance Appliance is to be used on a stable level flat non flammable surface the appliance should be protected from direct drafts and in a well ventilated place Only cooking vessels with a minimum of 250mm and a maximum of 300mm diameter are to be used with this appliance Take care that the primary air intakes located on the burner tube of this ap...

Page 3: ...ngers to tighten connection 3 Attach the other end of the hose with the regulator to the gas cylinder tightening using the two finger support posts 4 Turn the cylinder gas valve on in an anti clockwise direction for one full turn and then check the connections for leaks with soapy water if a leak is detected turn the cylinder gas valve Off and retighten all connections then retest OPERATING THE AP...

Page 4: ...irection for a lower flame 5 TURNING THE BURNER OFF If the appliance is no longer to be used and to reduce the risk of blocked gas jets caused by excess gas being left in the hose all remaining gas must be expelled from the hose assembly 1 With the flame still operating turn the valve on the gas cylinder in the clockwise direction until it is off Allow the flame to burn down then extinguish once a...

Page 5: ... with walls on all sides but with no overhead cover B Within a partial enclosure that includes an overhead cover and no more than two walls C Within a partial enclosure that includes an overhead cover and more than two walls the following must apply 1 At least 25 of the total wall area is completely open 2 30 or more in total of the remaining wall side back and front wall areas is open and unrestr...

Page 6: ...n Quadruple Ring Burner Size 563 x 335 x 115mm Weight 13kg Output 75 000BTU Gas Jet Burner 1 0 575mm Burner 2 1 000mm Burner 3 1 275mm Burner 4 1 475mm Consumption Inlet Pressure 2 75kPa Consumption 1 3kg hr 56 45Mj hr Code RB30 Description Double Ring Burner Size 420 x 162 x 85mm Weight 4 0kg Output 15 300BTU Gas Jet Burner 1 1 075mm Burner 2 0 600mm Consumption Inlet Pressure 2 75kPa Consumption...