7
GENERAL INfORMATION
1.7
Technical specifications
Performance combined with AMW P
Model
250 P
355 P
370 P
475 P
485 P
Model compatibility
Indoor unit
2 x AMW
35 P
3 x AMW 25 P
4 x AMW 25 P
Indoor unit max. number
2
3
4
Cooling performance [A35 / A27]
(1)
Nominal capacity
5,00
5,50
7,00
7,50
8,50
kW
Minimum capacity
1,30
2,10
2,40
3,20
kW
Maximum capacity
6,00
7,00
7,60
8,70
9,50
kW
Nominal power input
1,56
1,38
1,75
2,00
2,50
kW
Minimum power input
0,35
0,55
kW
Maximum power input
2,4
2,5
2,7
3,4
3,5
kW
Cooling energy data
(2)
Pdesign at 35 °C
5,00
5,50
7,00
7,50
8,50
kW
SEER
6,50
7,50
7,00
kW/kW
Energy class
A++
Annual energy cons.
269
258
332
379
456
kWh/
annum
Heating performance [A7 / A20]
(3)
Nominal capacity
5,70
6,80
7,60
8,60
9,60
kW
Minimum capacity
1,80
1,70
2,90
3,10
4,40
kW
Maximum capacity
6,60
7,60
8,50
10,00
10,50
kW
Nominal power input
1,54
1,55
1,80
2,15
2,40
kW
Minimum power input
0,55
kW
Maximum power input
2,45
2,2
2,3
3,1
3,4
kW
Enery data for Average climatic profile
(4)
Annual energy cons.
1820
1679
2012
2179
2503
kWh/
annum
Pdesign at -10 °C
5,20
4,70
6,00
6,30
7,00
kW
SCOP
4,00
4,20
4,00
kW/kW
Energy class
A+
Energy data for Warm climatic profile
(4)
Pdesign at +2 °C
2,80
3,20
3,40
3,70
kW
SCOP
5,10
4,80
5,30
5,00
4,60
kW/kW
Energy class
A+++
A++
Annual energy cons.
765
801
845
977
1123
kWh/
annum
(1)
Outdoor air: 35 °C D.b., Indoor air: 27 °C D.b. / 19 ° W.b.
(2)
In compliance with 626/2011 regulation
(3)
Outdoor air: 7 °C D.b. / 6 °C W.b., Indoor air: 20 °C D.b.
(4)
In compliance with EU 206/2012 regulation
Summary of Contents for AARIA MULTI 250 P