20
INSTALLATION
—
positioning in corners where dust, leaves, or any other
materials typically accumulate, which could compromise
the device efficiency by obstructing the airflow
—
situations in which the air expelled from the device might
enter the habitation through doors or windows, thus cre-
ating an inconvenience for the people inside
—
situations in which the air expelled from the device will
encounter resistance from opposing winds
—
direct exposure to sunlight and proximity to heat sources
9
Avoid placing the unit less than 1 metre away from radio and
video systems.
9
If the unit is installed in a windy location, fit an anti-wind
grille to protect the fan and check the correct functioning of
the unit.
9
Decide where to place the unit considering the length of
cooling lines and the maximum difference of height al-
lowed between the devices.
2.7
Recommended distances
The distances for the device installation and maintenance are
shown in the figure. The indicated spaces are necessary in order
to prevent the airflow from being blocked, as well as to allow
normal cleaning and maintenance operations to be carried out.
300
500
30
0
60
0
500
2.8
Positioning
R
AARIA MULTI R32
devices must:
—
be positioned on a level surface that is capable of support-
ing their weight
—
be positioned on a sufficiently rigid surface that will not
transmit any vibrations to the underlying or adjacent rooms
9
Use the anti-vibration supports supplied with the device.
A
B
C
D
Model
250 P
355 P
370 P
475 P
485 P
foot print dimensions
A
113,5
130
130
130
130
mm
b
583
630
630
630
630
mm
C
113,5
130
130
130
130
mm
D
319,5
368
368
368
368
mm
They can be placed on the floor or suspended on supporting
brackets.
Positioning on floor
1
Fastening screw M4
2
Anti-vibration element (supplied)
3
Spirit level
1
2
3
—
screw the unit to the ground
—
tighten using a torque wrench
—
apply a tightening torque of 3.5 Nm
Provide for lifting of the unit from the floor:
—
20 mm without conveying of the condensate outlet
—
90 - 100 mm to allow for the condensate discharge
9
If the device is installed in an area that is subject to heavy
snowfalls, place the unit in a raised position so as to pre-
vent the air flow from being blocked or install a roofing to
protect it.
9
Adequate anti-freeze systems should be used for installa-
tions in extremely cold areas, where there is a possibility of
freezing.