9
GENERAL INFORMATION
DESCRIPTION
INSIEME EVO
COND 25 B/130
LN
INSIEME EVO
COND 35 B/130
LN
Type of storage cylinder
Vitrified
Vitrified
Storage cylinder layout
Horizontal
Horizontal
Heat exchanger layout
Horizontal
Horizontal
Maximum power absorbed
24,5
27,7
kW
Rated heat input in DHW operation
Qmw
25
35
kW
DHW temperature setting range
40-65
40-65
°C
Storage cylinder capacity
130
130
l
Coil water capacity
6
6
l
Heat exchange surface area
1,32
1,32
m2
Production of domestic water with (
Δ
T 35°C) (*)
600
685
l/h
Water draw in 10 minutes with storage cylinder at 48°C
184
192
l
Water draw in 10 minutes with storage cylinder at 60°C
230
240
l
Specific flow rate (EN 13203)
23
24
l/min
Reset time (
Δ
T 35°C)
20
20
min
Maximum operating pressure of storage cylinder
6
6
bar
Volume of expansion vessel (DHW)
6
6
l
Precharge of expansion vessel (DHW)
3,5
3,5
bar
Insulation thickness
50
50
mm
Quantity/diameter/length of magnesium anode
1/22/400
1/22/400
mm
Flange internal diameter
130
130
mm
Length of 2-tube probe holder (Ø 8 mm)
210
210
mm
Maximum operating pressure of coil
3
3
bar
Maximum operating temperature
82
82
°C
Dissipation according to EN 12897:2006
∆
t= 45°C (environment 20°C and storage at
65°C)
120
120
W
Discharges according to UNI 11300
2,7
2,7
W/K
Domestic hot water continuous efficiency (DHW 10-
45°C)
80°C
∆t 20°C
24,5
27,7
kW
600
685
l/h
Running time to warm up the heater at 60°C
80°C
∆t 20°C
24
24
min
Thermal output coefficient NL according to DIN 4708 (**)
1,66
1,83
(*)
Inlet temperature of 10°C and average outlet temperature of 45°C with coil inlet temperature of 80°C.
(**)
The NL index indicates a number of apartments having 3.5 people that can be fully supplied, with a 140-litre bathtub and
two other drawing points.
DESCRIPTION
INSIEME EVO COND
25 B/130 LN
35 B/130 LN
Maximum adjustment temperature
82
82
°C
Minimum return temperature
20
20
°C
Boiler water capacity
37,3
38
l
Turbulators
20
28
n°
Volume of expansion vessel (CH)
12
12
l
Precharge of expansion vessel (CH)
1,5
1,5
bar
Maximum condensation at 100% rated heat output (40-30°C)
1,4
1,8
l/h
Index of protection
X0D
X0D
IP
Power supply
230 V - 50 Hz
230 V - 50 Hz
Absorbed power supply (max)
190
190
W
Consumption at full load
Elmax
190
190
W
Consumption at part load
Elmin
57
57
W
Electrical consumption in standby mode
Psb
18
18
W
LCV: Lower calorific value of fuel
HCV: Higher calorific value of fuel
Test conditions:
− Room temperature 22°C
− Atmospheric pressure 1018 mbar