71
COMMISSIONING AND MAINTENANCE
Heating programming
“
Group
”
1
“
Program Comfort Period
”
1
“
Comfort Setpoint
”
28.0
“
°C
”
“
ECO Setpoint
”
20.0
“
°C
”
“
Out of interval setpoint
”
“
Reduced
”
It supports adjusting the time programme for the CH zones with
the following parameters:
Period setting
Enables the user to select a period from 1 to 7. Period settings
enable the user to adjust the active periods for this zone.
−
Active days
: Selection of the day (s) on which the period
is active. Enables the user to disable the period set for
one or more days. When this parameter is set as inac-
tive, the other items on this menu are no longer used
and hidden from the view. The choice of active days is
between the following macro-groups: Sat-Sun, Mon-Fri,
Mon-Sun, or individual days: Mon, Tue, Wed,...
−
Interval 1 (hidden if Active Days is disabled)
: This param-
eter allows the user to regulate the starting and end time
of the period. The starting time must always be before
the finishing time.
−
Interval 2 (hidden if Active Days is disabled)
: Same as
interval 1. Interval added for the activated period.
−
Interval 3 (hidden if Active Days is disabled)
: Same as
interval 1. Interval added for the activated period.
“
Group
”
1
“
Program Comfort Period
”
71
“
Comfort Setpoint
”
28.0
“
°C
”
“
ECO Setpoint
”
20.0
“
°C
”
“
Out of interval setpoint
”
“
Reduced
”
“
External Zone
”
CH -
“
Period
”
1
“
Active Day(s)
”
“
Sunday
”
“
Interval 1
”
00:00
00:00
“
Interval 2
”
00:00
00:00
“
Interval 3
”
00:00
00:00
Comfort Set-point
Comfort temperature to be used when the zone is in a certain
period. (10 -30 °C)
ECO set-point
ECO temperature. Adjustable temperature that can be used out-
side set periods (5 – 20 °C).
Set-points outside the interval
Selection of the type of set-point to be used when a zone is not
on a set period by selecting between:
− Off
− Comfort
− Eco
− Anti-Freeze (is activated below 5°C NON-ADJUSTABLE)
− Reduced (Calculated as -10°C Comfort Set-point value)
DHW setting
“
Group
”
1
“
Program Comfort Period
”
1
“
Out of interval setpoint
”
“
On
”
It supports adjusting the time programme for the DHW zone.
Period setting
Enables the user to select a period from 1 to 7. Period settings
enable the user to adjust the active periods for this zone.
−
Active days
: Selection of the day (s) on which the period
is active. Enables the user to disable the period set for
one or more days. When this parameter is set as inac-
tive, the other items on this menu are no longer used
and hidden from the view. The choice of active days is
between the following macro-groups: Sat-Sun, Mon-Fri,
Mon-Sun, or individual days: Mon, Tue, Wed,...
−
Interval 1 (hidden if Active Days is disabled)
: This param-
eter allows the user to regulate the starting and end time
of the period. The starting time must always be before
the finishing time.
−
Interval 2 (hidden if Active Days is disabled)
: Same as
interval 1. Interval added for the activated period.
−
Interval 3 (hidden if Active Days is disabled)
: Same as
interval 1. Interval added for the activated period.
“
Group
”
DHW
“
Program Comfort Period
”
71
“
Comfort Setpoint
”
28.0
“
°C
”
“
ECO Setpoint
”
20.0
“
°C
”
“
Out of interval setpoint
”
“
Reduced
”
“
External Zone
”
DHW -
“
Period
”
1
“
Active Day(s)
”
“
Sunday
”
“
Interval 1
”
00:00
00:00
“
Interval 2
”
00:00
00:00
“
Interval 3
”
00:00
00:00
Set-points outside the interval
Selection of the type of set-point to be used when a zone is not
on a set period by selecting between:
− Off
− On