22
INSTALLATION
1m
T
T
L
L
A
C
A
Type C transformation accessory
C
Condensation exhaust system (not supplied)
T
Terminal
L
Maximum straight length
(This length must be reduced by 1 metre for every 90°
curve and by 0.5 metres for every 45° curve.)
Description
INSIEME EVOe 32 B/110 LN
L
MAX
Flue gas vent and
comburent air intake
30 (*)
m
L
MAX
Air inlet
15 (*)
m
(*)
This length must be reduced by 1 metre for every 90° curve
and by 0.5 metres for every 45° curve.
9
Use of flues longer than the specified maximum leads to a
loss of heat output from the boiler.
9
Never obstruct or choke the comburent air intake pipe.
Coaxial flues (Ø 80 / 125)
For these configurations, the type C transformation accessory
and the concentric flue gas exhaust accessory must be installed
(following the instructions supplied with the accessories them-
selves).
Coaxial flues can be oriented in whatever direction is most con-
venient for the room, provided the maximum specified lengths
are respected.
G
C
T
L
B
A
A
Type C transformation accessory
B
Concentric flue kit
C
Condensation exhaust system (not supplied)
G
Protective grille (not supplied)
T
Terminal
L
Maximum straight length
(This length must be reduced by 1 metre for every 90°
curve and by 0.5 metres for every 45° curve.)
Description
INSIEME EVOe 32 B/110 LN
L
MAX
7 (*)
m
(*)
This length must be reduced by 1 metre for every 90° curve
and by 0.5 metres for every 45° curve.
Summary of Contents for 20118250
Page 1: ...cod 20129503 rev 3 06 2019 INSIEME EVOe 32 B 110 LN EN INSTALLATION AND MAINTENANCE MANUAL...
Page 61: ...61...
Page 62: ...62...
Page 63: ...63...