Instructions for use
Rieber GmbH & Co. KG
17
# Observe connection value
Power is supplied via the electrically interlinked appliances, supply cable 230 / 400 V. The power
consumption on the buffet itself is 230 V.
The connection value comes from adding all power (in kW) of the connected electrical appliances and
installations. The power requirement of a consumer installation is the sum of the electrical power used
simultaneously.
NOTE
If the electrical connection value is exceeded, the power circuit is switched off. The maximum
permissible connection value is predetermined by the shape of the connecting plug.
►
Observe connection value:
≤ 10.5
kW
at
400
V
16 A
≤ 3.5
kW
at
230
V
16 A
.
# Couple buffets together correctly
WARNING
Danger of electric shock if handled incorrectly.
►
When electrically bridging the buffet with a connecting cable, make sure the cable
end is securely fixed. Fix the cable end by hand in the fixing bracket on the
underside of the buffet.
►
Do not let the cable hang down. Keep the buffet away from moisture.
See ‘Information on connecting the buffet’, page 14 ff.
# Do not switch lots of electrical appliances on and off simultaneously
ATTENTION
Risk of a cable fire. Peak currents occur if lots of connectible electrical appliances are
switched on and off simultaneously along the chain.
►
Do not switch lots of appliances on and off simultaneously.
►
Only pull out the mains plug after switching the appliance off.