background image

3 – English

GENERAL SAFETY RULES

WARNING:

Read and understand all instructions.

 Failure 

to follow all instructions listed below may result in 
electric shock, fire, and/or serious personal injury.

SAVE THESE INSTRUCTIONS

WORK AREA

 

Keep your work area clean and well lit. 

Cluttered 

benches and dark areas invite accidents. Floor must not 
be slippery from wax or dust.

 

Do not operate air compressors in explosive atmo-
spheres, such as in the presence of flammable liquids, 
gases, or dust.

 Power tools create sparks which may 

ignite the dust or fumes.

 

Keep bystanders, children, and visitors away while 
operating an air compressor. 

Distractions can cause you 

to lose control.

 

Operate air compressor in an open area at least 18 in. 
away from any wall or object that could restrict the 
flow of fresh air to ventilation openings.

ELECTRICAL SAFETY

 

Avoid body contact with grounded surfaces such as 
pipes, radiators, ranges, and refrigerators. 

There is an 

increased risk of electric shock if your body is grounded.

 

Don’t expose air compressors to rain or wet condi-
tions. 

Water entering an air compressor will increase the 

risk of electric shock.

 

Do not abuse the cord. Never use the cord to carry 
the air compressor or pull the plug from an outlet. 
Keep cord away from heat, oil, sharp edges, or moving 
parts. Replace damaged cords immediately. 

Damaged 

cords increase the risk of electric shock.

 

When operating an air compressor outside, use an out-
door extension cord marked “W-A” or “W”. 

These cords 

are rated for outdoor use and reduce the risk of electric 
shock.

PERSONAL SAFETY

 

Eye protection which conforms to ANSI specifications 
and provides protection against flying particles both 
from the FRONT and SIDE should ALWAYS be worn by 
the operator and others in the work area when load-
ing, operating, or servicing this product. 

Eye protection 

is required to guard against flying fasteners and debris, 
which could cause severe eye injury

.

 

The employer and/or user must ensure that proper 
eye protection is worn. 

We recommend a Wide Vision 

Safety Mask for use over eyeglasses or standard safety 
glasses that provide protection against flying particles 
both from the front and side. Always use eye protection 
which is marked to comply with ANSI Z87.1.

 

Additional safety protection will be required in some 
environments. 

For example, the working area may 

include exposure to a noise level which can lead to hear-
ing damage. The employer and user must ensure that any 
necessary hearing protection is provided and used by the 
operator and others in the work area. Some environments 
will require the use of head protection equipment. When 
required, the employer and user must ensure that head 
protection marked to comply with ANSI Z89.1 is used.

 

Stay alert, watch what you are doing, and use com-
mon sense when operating the air compressor. Do 
not use product while tired or under the influence of 
drugs, alcohol, or medication. 

A moment of inattention 

while operating an air compressor may result in serious 
personal injury.

 

Dress properly. Do not wear loose clothing or jewelry. 
Contain long hair. Keep your hair, clothing, and gloves 
away from moving parts. 

Loose clothes, jewelry, or long 

hair can be caught in moving parts.

 

Do not overreach. Keep proper footing and balance 
at all times. 

Proper footing and balance enables better 

control of the product in unexpected situations.

 

Use safety equipment. Always wear eye protection. 

Dust mask, nonskid safety shoes, hard hat, or hearing 
protection must be used for appropriate conditions.

 

Do not use on a ladder or unstable support. 

Stable 

footing on a solid surface enables better control of the 
air compressor in unexpected situations.

AIR COMPRESSOR USE AND CARE 

 

Do not exceed the pressure rating of any component 
in the system. 

 

Protect material lines and air lines from damage or 
puncture.

 Keep hose and power cord away from sharp 

objects, chemical spills, oil, solvents, and wet floors. 

 

Check hoses for weak or worn condition before each 
use, making certain all connections are secure. 

Do not 

use if defect is found. Purchase a new hose or notify an 
authorized service center for examination or repair.

 

Release all pressures within the system slowly. 

Dust 

and debris may be harmful.

 

Store idle air compressors out of the reach of children 
and other untrained persons. 

Air compressors are dan-

gerous in the hands of untrained users.

 

Maintain air compressors with care.

 Follow mainte-

nance instructions. Properly maintained products are 
easier to control.

 

Check for misalignment or binding of moving parts, 
breakage of parts, and any other condition that may 
affect the product’s operation. If damaged, have the 
air compressor serviced before using. 

Many accidents 

are caused by poorly maintained products.

Summary of Contents for OF60150VP

Page 1: ...CONTENTS General Safety Rules 3 4 Specific Safety Rules 4 5 Symbols 6 7 Electrical 8 Glossary of Terms 9 Features 9 Assembly 10 Operation 10 12 Maintenance 13 Troubleshooting 14 15 Illustrations 16 17...

Page 2: ...ier de quelle que mani re que ce soit les garanties en vigueur seront d clar es nulles et non avenues RIDGID et One World Technologies Inc d clineront toute responsabilit pour les pertes blessures et...

Page 3: ...ion will be required in some environments For example the working area may include exposure to a noise level which can lead to hear ing damage The employer and user must ensure that any necessary hear...

Page 4: ...leaks air or does not function properly Always disconnect the air supply and power supply before making adjustments servicing a product or when a product is not in use Do not attempt to pull or carry...

Page 5: ...feet is not recommended If in doubt use the next heavier gauge The smaller the gauge number the heavier the cord An undersized cord will cause a drop in line voltage resulting in loss of power and ove...

Page 6: ...compressors as far from the spray ing area as possible at least 15 feet from the spraying area and all explosive vapors Risk of Electrical Shock Hazardous Voltage Disconnect from power source before...

Page 7: ...r sanding sawing grinding drilling and other construction activities may contain chemicals including lead known to the State of California to cause cancer birth defects or other re productive harm Was...

Page 8: ...loss of power and the motor will overheat If the product does not operate when plugged into an outlet double check the power supply SPEED AND WIRING The no load speed of this product is approximately...

Page 9: ...cates the pressure in the air tank Air Filter Porous element contained within a metal or plastic housing attached to the compressor cylinder head which removes impurities from the intake air of the co...

Page 10: ...garage it should be in a room or enclosure provided for the purpose or should be 18 in or more above the floor WARNING Do not attach any tools to the open end of the hose until start up has been comp...

Page 11: ...on the air compressor will automatically turn back on when the designated tank air pressure drops below the preset pressure limit It will also shut off again when the desired pressure is reached OPERA...

Page 12: ...or MUST be removed from service by the end of the year shown on the data label Use of the air compressor after this date increases the risk of an air tank rupture which could result in serious persona...

Page 13: ...can be removed Remove the screw and the back from the air filter housing and set aside Remove the foam filter from the air filter housing Wash with warm soapy water and rinse clean Set aside and allo...

Page 14: ...icient power from receptacle Insufficient power from extension cord Check with voltmeter Check for proper gauge wire and cord length Take compressor to service center Take compressor to service center...

Page 15: ...ntinuously Defective pressure switch Excessive air usage Piston seal is worn Take compressor to service center Decrease air usage compressor not large enough for tool s requirement Replace piston seal...

Page 16: ...protection oculaire ad quate soit utilis e Nous recommandons d utiliser un masque facial champ de vision se portant par dessus des lunettes de vue ou de s curit et pot geant des d bris projet s sur l...

Page 17: ...le flexible d air branch Ne pas pointer un outil quel qu il soit vers soi ou d autres personnes Ne pas utiliser cet outil s il ne comporte pas d autocollant d avertissement Ne pas utiliser un outil q...

Page 18: ...e pi ce n est bloqu e ou cass e v rifier la fixation de chaque pi ce et s assurer qu aucun autre probl me ne risque d affecter le bon fonctionnement de l outil Toute protection ou pi ce endommag e doi...

Page 19: ...possible des zones de pulv risation au moins 4 6 m 15 pi de la zone de pulv risation et de toutes vapeurs explosives Risque de choc lectrique Tension dangereuse D brancher de la prise secteur avant d...

Page 20: ...nir des produits chimiques notamment du plomb qui selon l tat de la Californie peuvent causer le cancer des anomalies cong nitales et d autres dommages au syst me reproducteur Bien se laver les mains...

Page 21: ...ourant r sidentiel standard 60 Hz Ne pas utiliser cet outil sur une source de courant continu c c Une chute de tension importante causerait une perte de puissance et une surchauffe du moteur Si le com...

Page 22: ...l ment poreux contenu dans un bo tier en m tal ou plastique mont sur la culasse du compresseur pour d barasser l air d alimentation de toutes ses impuret s R servoir d air Composant cylindrique conte...

Page 23: ...mand s peut entra ner des blessures graves AVERTISSEMENT Ce produit comporte des pi ces telles que des interrupteurs ressort qui ont tendance produire des arcs ou des tincelles Par cons quent lorsque...

Page 24: ...risation de peinture TRANSPORT Voir la figure 2 page 16 Enrouler le cordon autour de l appareil et le fixer fermement comme illustr Le crochet de transport pour cloueuse espace de rangement permet d...

Page 25: ...ntra ner des blessures graves n Fermer le robinet de purge en le tournant fond vers la droite UTILISATION AVERTISSEMENT RISQUE D CLATEMENT Tous les r servoirs d air comprim ont une dur e de vie utile...

Page 26: ...er le logement Retirer la vis et le retour du logement du filtre air et mettre de c t Retirer le filtre en mousse du logement du filtre air Laver l eau savonneuse ti de puis rincer Mettre de c t et la...

Page 27: ...le minimum Le moteur ronfle mais ne tourne pas ou tourne lentement Tension insuffisante Calibre ou longueur de prolongateur incorrect Enroulement de moteur ouvert ou court circuit Soupape antiretour...

Page 28: ...ir de sortie trop humide Exc dent d eau dans le r servoir Humidit excessive Purger le r servoir Emmener le compresseur un endroit moins humide utiliser un filtre air en ligne Le moteur du compresseur...

Page 29: ...art culas que salgan disparadas del FRENTE y de los LADOS Se requiere protecci n ocular como protecci n contra sujetadores y desechos que salgan disparados los cuales pueden causar lesiones oculares s...

Page 30: ...Mantenga la manguera y el cord n de corriente lejos de objetos afilados productos qu micos derramados aceite solventes y pisos mojados Antes de usar la unidad revise las mangueras para ver muestran d...

Page 31: ...nte y desempe ar la funci n a la que est destinada Verifique la alineaci n de las partes m viles que no haya atoramiento de las mismas que no haya piezas rotas el montaje de las piezas y cualquier otr...

Page 32: ...e donde haya presentes chispas o flamas Mantenga los compresores tan lejos del rea de pintura y de vapores explosivos como sea posible por lo menos a 4 6 m 15 pies Riesgo de descarga el ctrica Voltaje...

Page 33: ...erilado taladrado y otras actividades de la construcci n contienen sustancias qu micas reconocidas por el estado de California como causantes de c ncer defectos cong nitos y otras afecciones del apara...

Page 34: ...60 Hz No utilice esta herramienta con corriente continua c c Una ca da considerable de voltaje causa una p rdida de potencia y el recalentamiento del motor Si el compresor no funciona al conectarlo e...

Page 35: ...e metal o pl stico unido al cilindro de la culata del cilindro del compresor el cual sirve para eliminar las impurezas del aire de entrada del compresor Tanque de aire Es un componente cil ndrico que...

Page 36: ...a piezas como interruptores de acci n inmediata recept culos y piezas similares que tienden a producir arcos o chispas y por lo tanto cuando dicho equipo est ubicado en una cochera debe estar en un cu...

Page 37: ...e la manguera desconectado n Presione hacia atr s del acoplador de conexi n r pida de 6 35 mm 1 4 pulg n Mientras lo sujeta firmemente tire del adaptador de aire de conexi n r pida que est conectado a...

Page 38: ...MIENTO ADVERTENCIA RIESGO DE ESTALLIDO Todos los tanques de aire comprimido tienen una vida til limitada La vida til puede estar afectada por gran cantidad de factores como las condiciones de funciona...

Page 39: ...re el tornillo y la parte trasera del alojamiento del filtro de aire y ap rtelos Retire el filtro de espuma del alojamiento del filtro de aire Lave con agua caliente y jab n y enjuague bien Ap rtelo y...

Page 40: ...el tanque desciende a la presi n de activaci n El motor zumba pero no funciona o lo hace con lentitud Voltaje bajo Cord n de extensi n de calibre o longitud equivocados El devanado del motor tiene cor...

Page 41: ...e descarga Cantidad excesiva de agua en el tanque de aire Alta humedad Drene el tanque Lleve la unidad a un lugar de menor humedad use un filtro de aire en l nea El compresor funciona continuamente In...

Page 42: ...e r gulateur de pression perilla de regulaci n de presi n K Quick connect coupler coupleur ressort acoplador de conexi n r pida OF60150VP Fig 2 A Nailer not provided cloueuse non fourni clavadora no i...

Page 43: ...a presi n Fig 6 A Safety valve soupape de s ret boquilla de la seguridad B Pull to release pressure pousser pour rel cher la pression tire para liberar la presi n Fig 7 A Drain valve soupape de vidang...

Page 44: ...rmations pertinentes lors de tout appel t l phonique ou visite Pour obtenir l adresse du centre de r parations agr le plus proche t l phoner au 1 866 539 1710 ou visiter notre site www ridgid com NO D...