Motor Specifications and Electrical Requirements
(continued)
110-120 Volt, 60 Hz. Tool
Information
NOTE: The plug supplied on your tool
may not fit into the outlet you are planning
to use. Your local electrical code may
require slightly different power cord plug
connections. If these differences exist
refer to and make the proper adjustments
per your local code before your tool is
plugged in and turned on.
In the event of a malfunction or break-
down, grounding provides a path of least
resistance for electric current to reduce
the risk of electric shock. This tool is
equipped with an electric cord having an
equipment grounding conductor and a
grounding plug, as shown. The plug must
be plugged into a matching outlet that is
properly installed and grounded in accor-
dance with all local codes and ordi-
nances.
Do not modify the plug provided. If it will
not fit the outlet, have the proper outlet
installed by a qualified electrician.
A temporary adapter may be used to con-
nect this plug to a 2-prong outlet, as
shown, if a properly grounded three prong
outlet is not available. This temporary
adapter should be used only until a prop-
erly grounded three prong outlet can be
installed by a qualified electrician. The
green colored rigid ear, lug and the like,
extending from the adapter must be con-
nected to a permanent ground such as a
properly grounded outlet box.
NOTE: In Canada the use of a temporary
adapter is not permitted by the Canadian
electrical code.
Improper connection of the equipment
grounding conductor can result in a risk of
electric shock. The conductor with insula-
tion having an outer surface that is green
with or without yellow stripes is the equip-
ment grounding conductor. If repair or
replacement of the electric cord or plug is
necessary, do not connect the equipment-
grounding conductor to a live terminal.
If the grounding instructions are not com-
pletely understood, or if you are in doubt
as to whether the tool is properly
grounded check with a qualified electri-
cian or service personnel.
WARNING: If not properly
grounded, this tool can cause an
electrical shock, particularly
when used in damp locations, in
proximity to plumbing, or out of
doors. If an electrical shock
occurs there is the potential of a
secondary hazard, such as your
hands to hit the cutting tool.
NOTE: The adapter illustrated is for use
only if you already have a properly
grounded 2-prong outlet.
NOTE: In Canada the use of a temporary
adapter is not permitted by the Canadian
Electrical Code.
3-Prong
Adapter
2-Prong
Outlet
Make sure this
Is Connected
Ground
Plug
to a Known
Grounding Lug
Properly
Grounded
3-Prong Plug
Grounding
Prong
3-Prong Outlet