Electrical
Supply voltage
X1
Power supply
Type
1-phase (1~)
3-phase (3~)
Current
1L1
3L2
5L3
N
*
RCB (A2)
RCB (A2)
RCB (A2)
RCB (A2)
Input
Input
Input
Input
RCB-A
1x 115 VAC
1x 230 VAC
RCB-A
-
-
3x 208 VAC
3x 400 VAC
RCB-B
3x 400 VAC
RCB-C
3x 440-480 VAC
3x 600 VAC
Max 12 A
X2
Power supply
Type
2T1
4T2
6T3
N
*
Electric motor (EM)
Electric motor (EM)
Electric motor (EM)
Electric motor (EM)
Output
Output
Output
Output
*N is only there on RCB-A.
X3
RCB-A
Transformer
Supply voltage
1 2 3 4 5
Type
1-phase (1~)
3-phase (3~)
Current
1~
Loop connection
1x 115 VAC
N.A.
~16 mA
1~
Loop connection
1x 230 VAC
N.A.
~10 mA
3~
Loop connection
N.A.
3x 208 VAC
~10 mA
3~
Loop connection
N.A.
3x 400 VAC
~ 4 mA
(X3)
RCB-B
Transformer
Supply voltage
1 2 3 4 5
Type
3-phase (3~)
Current
3~
N.A.
N.A.
N.A.
3x 400 VAC
X3
RCB-C
Transformer
Supply voltage
1 2 3
Type
3-phase (3~)
Current
3~
Loop connection
N.A.
3x 440-480 VAC
3~
Loop connection
N.A.
3x 600 VAC
X4
PTC IN
Type
Supply voltage
Current
1
PTC
Input
0.25 V DC
1 mA
2
PTC’
Power supply
0.25 V DC
1 mA
X5
Fault contact OUT
Type
Supply voltage
Current
1
Not connected
Loop-connection pin
Max 350 V
Max 50 mA
2
Fault OUT
Switching contact
Max 350 V
Max 50 mA
3
Fault OUT’
Switching contact
Max 350 V
Max 50 mA
X6
ACS
Type
Supply voltage
Current
1
Direction B
Input
24 V AC/DC
10.5/10 mA
2
Common
Ground
Ground
10.5/10 mA
3
Direction A
Input
24 V AC/DC
10.5/10 mA
X7
RPU
Type
Supply voltage
Current
1
+24V
Power supply
24 V
DC
50 mA
2
RPU CALIBRATION A
Output
24 V
DC
0.5/1 mA
3
RPU CALIBRATION B
Output
24 V
DC
0.5/1 mA
4
Neutral wire
Power supply
Ridder Drive Systems B.V.
T
+31 (0)341 416 854 -
F
+31 (0)341 416 611 -
I
11