10 February, 2005
SERVICE PROGRAM MODE
5-65
Service
Tables
7
Mode No.
(Class 1, 2, and 3)
Function / [ Setting ]
Proc Cont Cnter (Process Control Counter)
908
1
Proc Cont Cnter
Displays the process control counter.
[0 ~ 9999999 /
0
/ 1 sheet/step]
Proc Cont Reset (Process Control Reset)
909
1
Proc Cont Reset
Resets the process control counter.
Oil Cnter (Oil Counter)
913
1
Oil Cnter
Displays the oil supply unit counter.
[0 ~ 65535 /
0
/ 1 sheet/step]
Oil Cln Cnt Rst (Oil Clean Counter Reset)
914
1
Oil Cln Cnt Rst
Resets the oil cleaner counter.
Proc Error Log (Process Error Log)
1 Log
1
2 Log
2
915
3 Log
3
Displays the latest three process control error logs.
The following are the error codes:
Development unit initial settings errors:
•
110: Incorrect image detected by cyan ID sensor
•
116: Incorrect image detected by magenta ID
sensor
•
118: No black image
Development bias settings errors:
•
113: Incorrect image detected by cyan ID sensor
•
114: Incorrect image detected by magenta ID
sensor
•
115: Incorrect image detected by yellow ID sensor
•
123: Incorrect image detected by black ID sensor
ID sensor errors:
•
103: ID sensor error
•
104: ID sensor unable to detect image
•
105: OPC belt not detected
Machine Counter
920
1
Machine Counter
[0 ~ 0xFFFFFFF /
0
/ 1 /step]
Machine Cnt Clr (Machine Counter Clear)
921
1
Machine Cnt Clr
Clears the machine counter.
Toner End Cnter (Toner End Counter)
1 K
Toner
2 C
Toner
3 M
Toner
922
4 Y
Toner
Displays the toner end counter, which indicates the
possible print count after a toner near end.
Toner End Cnt Clr (Toner End Counter Clear)
1 K
Toner
2 C
Toner
3 M
Toner
4 Y
Toner
923
100 All
Clears the toner end counter (SP7-922).
The machine goes back to the normal operation mode if
the toner end counter is cleared.
Charger Cln Cntr (Charger Clean Counter)
924
1
Charger Cln Cntr
Displays how many times the charge corona wire has
been cleaned.
[0 ~ 9999999 /
0
/ 1 sheet/step]
SP7-926 resets the counter.