Work ID change request
Message ID
Message name
Description
0x00000006
Work ID change request
Change the work ID on the SC-10A from the
other device.
Perform an operation equivalent to CHG
WORK ID of the external IO.
Message format
Address
bit
31
16
15
0
0x0000
Message ID
0x0004
Device ID
0x0008
Device name
0x0048
Work ID
Address
Size
Attribute
Field name
Description
0x0000
4 byte
uint32
Message ID
Message unique ID
0x0004
4 byte
uint32
Device ID
Use the lower 4 bytes of the MAC address
of the SC-10A.
0x0008 - 0x0047
64 byte
char
Device name
Up to 50 half-width alphanumeric
characters long
0x0048 - 0x0087
64 byte
char
Work ID
Up to 50 half-width alphanumeric
characters long