RICOH SC-10 SERIES
Socket Mode Function Operating Instructions Ver.1.0.0
45/66
Address
Size
Attribute
Field name
Description
0x02a0
2 byte
int16
Work item last
result
0: OK
-1: Failed
0x02a2
2 byte
uint16
Elapsed time
(seconds)
Set the work elapsed time in seconds.
Work item completed notification (stop)
Message ID
Message name
Description
0x10010005
Work item completed notification (stop)
Message to send from the SC-10A after stop
execution from the UI or external IO.
Message format
Address
bit
31
16
15
0
0x0000
Message ID
0x0004
Device ID
0x0008
Device name
0x0048
Year
Month
Day
0x0088
Hour
Minute
Second
reserve
0x00c8
Work ID
0x0108
Work instruction list
0x010c
Work item
0x0110
Work item last result
reserve
Address
Size
Attribute
Field name
Description
0x0000
4 byte
uint32
Message ID
Message unique ID
0x0004
4 byte
uint32
Device ID
Equipment unique ID
0x0008 - 0x0047
64 byte
char
Device name
Up to 50 half-width alphanumeric
characters long
0x0048
2 byte
uint16
Year
Set the time of the SC-10A.
0x004a
1 byte
uchar
Month
Set 1 to 12 for the time of the SC-10A.
0x004b
1 byte
uchar
Day
Set 1 to 31 for the time of the SC-10A.
0x004c
1 byte
uchar
Hour
Set 0 to 23 for the time of the SC-10A.
0x004d
1 byte
uchar
Minute
Set 0 to 59 for the time of the SC-10A.
0x004e
1 byte
uchar
Second
Set 0 to 59 for the time of the SC-10A.
0x004f
1 byte
uchar
reserve
Unused area
0x0050 - 0x008f
64 byte
char
Work ID
Up to 50 half-width alphanumeric
characters long
0x0090 - 0x00cf
64 byte
char
Work instruction
list
Up to 50 half-width alphanumeric
characters long
0x00d0 - 0x00ff
64 byte
char
Work item
Up to 50 half-width alphanumeric
characters long
0x0100
2 byte
int16
Cause of stop
0: Stopped from UI
1: Stopped from external IO
0x0102
2 byte
uint16
Elapsed time
(seconds)
Set the work elapsed time in seconds.