Matching of multiple work items of one work ID
When multiple work items are registered to one work ID, multiple start requests/responses and work item completed
notifications/responses are repeated for one work ID start request/response.
The execution order does not matter as long as the work items are within one work ID.
SC-10A
対向機
Start
要求
(Item1)
Start
応答
作業
Item
完了通知
(Item1
マッチング
)
作業
Item
完了応答
作業
ID
開始要求
作業
ID
開始応答
作業
ID
完了通知
作業
ID
完了応答
Start
要求
(Item2)
Start
応答
作業
Item
完了通知
(Item2
マッチング
)
作業
Item
完了応答
All work items registered
to the work ID are
executed.
When the work items within
the work ID finish, a work
ID completed notification is
sent.
Other device
SC-10A
Work ID start request
Work ID start response
Start request (Item 1)
Start response
Work item completed notification
(Item 1 matching)
Work item completed
Start request (Item 2)
Start response
Work item completed notification
(Item 2 matching)
Work item completed
Work ID completed notification
Work ID completed response