164
Error Message
This drive cannot be
formatted.
This drive is read-only.
Illegal file name.
No space in the drive.
Already contents same
file name.
Too deep folder tree.
Failed to delete.
This file / folder cannot
be transferred.
This file name is used by
Camera.
Cannot move folder to
Camera.
Folders cannot be added
anymore.
Internal Error.
This folder already
contain a file named XX.
This folder already
contain a read-only file
named XX.
Cannot connect to
Camera. Please check
connection.
Communication failed.
Please check connection.
Please choose the image
to transfer.
Insufficient memory:
please close other
applications.
Failed to access to the
file
●
●
TWAIN Internal Error
Failed to initialize
Windows Socket.
Cause and Remedy
Specified drive cannot be formatted. Restart
camera and try again.
Specified drive is write-prohibited. Cancel write
protection.
Incorrect file name specified when copying/moving.
Specify correct file.
Copying/Moving not possible as drive is full. Delete
unwanted files.
File name specified when copying/moving already
exists. Specify different file name.
Cannot create folder as folder layers too deep.
Make layers more shallow.
Deletion of specified file prohibited.
Transfer of specified file/folder prohibited.
Specified file name is used by this software. Specify
other file name.
Folders in a PC cannot be transferred to camera.
Create a folder in camera first and then transfer
files in the folders of the PC.
Limit of number of folders has been reached.
Delete unwanted folders.
Error has occurred. Restart camera. If error
persists, reinstall RDC-i Software from CD-ROM
supplied.
File name specified when copying/moving already
exists. To overwrite, click on [OK].
File name specified when copying/moving already
exists. To overwrite, click on [OK].
Camera not correctly connected. Check connection.
Camera not correctly connected. Check connection.
Attempted to execute transfer without selecting
image file. Select image file before transferring.
Insufficient memory in PC. Reboot PC and perform
operation without starting up other applications.
Drive has not been ready to access, or folder or file
does not exist.
Error occurred in TWAIN.DLL. Reinstall TWAIN
driver from CD-ROM supplied.
Error occurred when creating Windows socket.
Reinstall WinSock.
Summary of Contents for RDC-i500
Page 8: ...6 ...
Page 28: ...26 ...
Page 102: ...100 ...
Page 146: ...144 ...
Page 156: ...154 ...
Page 173: ...171 Appendix MEMO ...
Page 180: ...178 MEMO ...