T
echnical
B
ulletin
PAGE: 75/75
Reissued:21-Apr-14
Model:
Aries-P1.5/C1.5
Date:
10-Mar-14
No.:
RM077107b
5. Select “Advanced Setting”. (Photo 5)
6. Select “Fusing Heat Roller Temperature Adj” and change the fusing temperature with
the “
+
”
and “
–
”
buttons. Decrease the temperature about 10 degrees from the default
temperature. (Photos 6 & 7)
Photo 5
Photo 6
Photo 7
Tips
1) If gloss lines/streaks do not disappear even after decreasing the temperature, further
decrease the temperature. However, if resulting in insufficient fusing, increase the
temperature 5 degrees and check if gloss lines/streaks are observed on the printouts.
2) Take notes of the original (default) fusing temp before making any changes because
you may have to switch back to the original stripper plate (p/n: M0774491), if gloss
lines/streaks with the new stripper plate (p/n: M0774445) cannot be resolved.
Summary of Contents for pro c901
Page 50: ...Technical Bulletin PAGE 14 44 Model Aries P1 5 C1 5 Date 17 Feb 11 No RM077018 Page 133 to 149...
Page 63: ...Technical Bulletin PAGE 27 44 Model Aries P1 5 C1 5 Date 17 Feb 11 No RM077018 Page 182 to 203...
Page 266: ...Technical Bulletin PAGE 2 2 Model Aries P1 5 C1 5 Date 26 Jan 12 No RM077059...
Page 290: ...Technical Bulletin PAGE 2 2 Model Aries P1 5 C1 5 Date 13 Feb 12 No RM077064...
Page 441: ...Technical Bulletin PAGE 2 2 Model Aries P1 5 Date 12 Dec 13 No RM077101...