T
echnical
B
ulletin
PAGE: 56/75
Reissued:21-Apr-14
Model:
Aries-P1.5/C1.5
Date:
10-Mar-14
No.:
RM077107b
- Procedure 1 -
The goal of this procedure is to decrease the Tc (toner concentration) to allow proper
removal of remaining developer and achieve optimum ratio of toner against developer
when initializing the new developer.
IMPORTANT:
Make sure this “Procedure 1” is carried out before “Procedure 2”.
1-1. Check the current Vt values in SP 3-001-001~004.
If the current Vt value is
equal to or greater than 2.4V
, complete the procedure.
If the current Vt value is
smaller than 2.4V
, proceed to step 2.
1-2. Change the default (0: PID) to
“1: No toner supply”
in SP3-301-001~004.
1-3. Print full-page solid patterns for the affected color(s) by referring to table 3 below
which describes the approximate required number of copies of the full-page solid
pattern according to the Vt confirmed in step 1.
If more than one color is affected, specify 2 affected colors when printing the solid
patterns to save time and paper, i.e. R (Y+M), G (Y+C), B (M+C).
* When printing the test pattern, black can also be mixed with the affected color, for
instance, K+Y.
* Work time can be reduced by using the copy function for the Copier model, and
printing the patterns from the Command Work Station using the calibration chart
(which allows to specify number of copies) for the Printer model.
Table 3:
Reference for required number of copies of the full-page solid pattern
Current Vt value (V)
SP3-001-001~004
Required number of copies of
the full-page solid pattern
Long edge
(A3, B4, DLT)
Short edge
(A4, LT)
2.2
13
26
2.0
26
52
1.8
39
79
1.6
52
105
1.4
66
131
1-4. Set the toner supply mode SP (SP3-301-001~004; Table 2) back to the default “0:
PID”.
Table 1: Current Vt Value Display
001
002
003
004
SP
3-001
ID Sn: Vt display Current val: K
ID Sn: Vt display Current val: C
ID Sn: Vt display Current val: M
ID Sn: Vt display Current val: Y
Table 2: Toner Supply Mode
Default
Change to
001
0: PID
1: No toner supply
002
0: PID
1: No toner supply
003
0: PID
1: No toner supply
004
0: PID
1: No toner supply
3-301
SP
Tnr Supply DFU K
Tnr Supply DFU C
Tnr Supply DFU M
Tnr Supply DFU Y
IMPORTANT
Make sure to set the toner supply mode (SP3-301-001~004) back to the
default “0: PID” before completing the procedure, otherwise toner will
not be supplied and cause problems.
Summary of Contents for pro c901
Page 50: ...Technical Bulletin PAGE 14 44 Model Aries P1 5 C1 5 Date 17 Feb 11 No RM077018 Page 133 to 149...
Page 63: ...Technical Bulletin PAGE 27 44 Model Aries P1 5 C1 5 Date 17 Feb 11 No RM077018 Page 182 to 203...
Page 266: ...Technical Bulletin PAGE 2 2 Model Aries P1 5 C1 5 Date 26 Jan 12 No RM077059...
Page 290: ...Technical Bulletin PAGE 2 2 Model Aries P1 5 C1 5 Date 13 Feb 12 No RM077064...
Page 441: ...Technical Bulletin PAGE 2 2 Model Aries P1 5 Date 12 Dec 13 No RM077101...