T
echnical
B
ulletin
PAGE: 15/15
Reissued:16-Oct-12
Model:
Aries-C1.5 (D095) / Aries-P1/.5(M077)
Date:
8-Nov-2012
No.:
RM077077b
Procedure 3: Manual Toner Refreshing
While Procedures 1 and 2 are SP modifications to prevent problem occurrences, the
following is a troubleshooting procedure to resolve a problem that is present and
caused by toner degradation.
3-1. Do “No.208 Execute Toner Refreshing” in the Adjustment Settings for Skilled
Operators Menu so that old toner/developer are removed and do not clog the
doctor gap.
3-2. Run the customer job.
Are the results accepted by the customer?
Yes:
Finish
No: Repeat the above step, because the development unit still contains
degraded toner.
3-3. Replace the developer of the affected color by referring to the procedures
described in RTB RM077072a, if mottled effects are still observed after
repeating the above steps twice.