SH-MF1 Training
121
Slide 121
Toner Supply and Development
The toner tank (1) holds sufficient toner for the entire life of the AIO.
The agitator (2) moves toner to the toner supply roller (3).
The supply roller provides toner to the development roller (4).
The metering blade (5) controls the amount of toner on the development
roller.
The toner on the development roller develops the latent image on the drum
as it rotates past.
The high voltage supply applies the following:
¾
-600V to the development roller
¾
-1550V to the charge rollers
¾
-110V to the supply roller
¾
-490V to the metering blade
The development components – drum, development roller, metering blade, and
supply roller – are in contact. (= no photoconductor gap nor doctor gap.)
Relative peripheral velocities: OPC 1, Development roller 1.2, Charge roller
more than 1.2
This AIO uses mono-component toner. Therefore, no toner density sensor or
image density sensor is required.
The toner is negatively charged.
Summary of Contents for M052
Page 3: ...SH MF1 Training 3 Slide 3 PRODUCT OUTLINE Introduction No additional notes ...
Page 12: ...SH MF1 Training 12 Slide 12 Product Outline New Features No additional notes ...
Page 22: ...SH MF1 Training 22 Slide 22 Product Outline Options No additional notes ...
Page 45: ...SH MF1 Training 45 Slide 45 Transporting the Machine No additional notes ...
Page 47: ...SH MF1 Training 47 Slide 47 Maintenance No additional notes ...
Page 87: ...SH MF1 Training 87 Slide 87 Scanner No additional notes ...
Page 112: ...SH MF1 Training 112 Slide 112 Laser Exposure No additional notes ...
Page 117: ...SH MF1 Training 117 Slide 117 All In One Cartridge AIO ...
Page 127: ...SH MF1 Training 127 Slide 127 Fusing No additional notes ...
Page 135: ...SH MF1 Training 135 Slide 135 Paper Exit No additional notes ...
Page 167: ...SH MF1 Training 167 Slide 167 One bin Tray M053 only No additional notes ...