10 October, 2002
TECH MODE
5-3
Service
Tables
5.1.3 TECH MODE OPTIONS
In TECH mode, press User Tools, then press “
◄
” or “
►
” until “TECH MODE”
appears in the display. Press Start/Enter.
The following options are available.
NOTE:
If necessary, print System Data List in TECH mode.
This list shows all current system data settings including the TECH MODE
options. To print the system data list, press Report/Help. Then press “
◄
” or
“
►
” until “SYSTEM DATA” appears in the display. Then press Start/Enter.
MODEM SPEED
•
You can set the maximum modem speed.
•
Communication is done with the modem automatically set at a lower speed.
When communicating with another modem at lower speed, communication
proceeds where modem speed is low for transmission/ reception. It is
recommended to set 33600 bps as the default.
DIALING MODE
•
Selecting the dialing mode depends on the user's line status.
•
TONE: Electrical dial type.
•
PULSE: Mechanical dial type.
SEND FAX LEVEL
•
You can set the level of the transmission signal. Normally, the Tx level should be
under –12 dBm. The level within the range of 0 to –15 dBm is acceptable.
CAUTION:
This is set in the factory before shipment. These settings should never
be changed.
PAUSE TIME
•
Pause time mean delay time (unit: second) inserted between dial number signal
and the next number of signal in the automatic dial (One touch, Speed dial,
Redial) and the manual dial.
CAUTION:
This is set in the factory before shipment. These settings should never
be changed.
REDIAL INTERVAL
•
If the remote machine is busy after the machine has sent a fax using automatic
dialing, the machine automatically redials the number. You can select the time
interval between automatic redial attempts. Enter the desired redial interval using
the number keypad: 1 through 15 minutes.