B245/B276/B277/B268/B269 Service Manual
18-Jan-06
264
AOF
When AOF is off, the engine controller is unable to start the Night/Off Mode. The user should
keep AOF on (
> System Settings > Key Operator Tools > AOF).
Timers
The engine controller references the Energy Saver Timer to start the Low Power Mode, and
references the Auto Off Timer to start the Night/Off Mode. The user can set these timers (
> System Settings > Timer Settings).
The Energy Saver Timer and the Auto Off Timer start at the same time (t
0
) when the machine
ends all jobs or when the user ends all manual operations. Note that the Auto Off Timer does
not wait for the Energy Saver Timer. Therefore, if the user specifies a smaller value in the
Energy Saver Timer, the Auto Off Timer expires earlier than the Energy Saver Timer. In a
case like this, the Low Power Mode is not activated. Instead, the engine controller starts the
Night/Off Mode when the Auto Off Timer expires.
Specified value
Low Power Mode
Night/Off Mode
Energy Saver Timer > Auto Off Timer
Can start
Can start
Energy Saver Timer = Auto Off Timer
Cannot start
Can start
Energy Saver Timer < Auto Off Timer
Cannot start
Can start
Recovery
Any of the following operations brings the machine back to the Operating Mode:
The power switch is pressed.
Originals are set on the document feeder.
The platen cover (or document feeder) is opened.
Summary of Contents for K-C3
Page 218: ...B245 B276 B277 B268 B269 Service Manual 18 Jan 06 209 ...
Page 220: ...B245 B276 B277 B268 B269 Service Manual 18 Jan 06 211 ...
Page 270: ...B245 B276 B277 B268 B269 Service Manual 18 Jan 06 261 ...
Page 285: ...B245 B276 B277 B268 B269 Service Manual 18 Jan 06 276 Machine Configuration ...