4. SERVICE TABLES AND PROCEDURES
4.1. SERVICE LEVEL FUNCTIONS
4.1.1. Bit Switch Programming (Function 91)
1. Function 5 1 9 9 1
then immediately Yes
FUNCTION Y/
∇
9 SERVICE FUNCTIONS
2. 9 1 Yes
DEFAULT: 0000 0000
BITSW 00: 0000 0000
Bit 7 is displayed at the left, and bit 0 at
the right.
3. Increment bit switch: #
Decrement bit switch: *
Example: Display bit switch 3: # x 3
DEFAULT: 0000 0000
BITSW03: 0000 0000
4. Adjust the bit switch.
Example: To change the value of bit
7, press 7
DEFAULT: 0000 0000
BITSW03: 1000 0000
5. Either:
•
Adjust more bit switches - go to step 3.
•
Finish - Function
4.1.2. System Parameter List (Function 92)
1. Function 5 1 9 9 1
then immediately Yes
FUNCTION Y/
∇
9 SERVICE FUNCTIONS
2. 9 2 Yes
START
SYSTEM REPORT
3. Start
After printing, press Function
4
SERVICE TABLES AND PROCEDURES
November 30th, 1991
SERVICE LEVEL FUNCTIONS
4-1
Summary of Contents for FAX500