4.3. NCU PARAMETERS
The following tables give the RAM addresses and units of calculation of the
parameters that the machine uses for ringing signal detection and automatic
dialing. The factory settings are also given. Most of these must be changed
by RAM read/write (Function 95), but some can be changed using NCU Pa-
rameter programming (Function 96); if Function 96 can be used, this will be
indicated in the Remarks column. The RAM is programmed in hex code un-
less (BCD) is included in the Unit column.
When using RAM read/write, you must add the bank number before the four-
digit RAM address number. See section 4-1-6 for details.
Address
Function
Unit
Remarks
413B
Country code (NCU parameters
only)
Hex
Function 96 (parameter 00).
413C
Line current detection time
20 ms
Line current is not detected
if 413C contains FF.
413D
Line current wait time
413E
Line current drop detect time
413F
PSTN dial tone upper frequency
limit (HIGH)
Hz (BCD)
See Note 2.
4140
PSTN dial tone upper frequency
limit (LOW)
4141
PSTN dial tone lower frequency
limit (HIGH)
4142
PSTN dial tone lower frequency
limit (LOW)
4143
PSTN dial tone detection time
20 ms
If 4143 contains FF, the
machine pauses for the
pause time (4147).
4144
PSTN dial tone reset time
160 ms
4145
PSTN dial tone continuous tone
time
20 ms
4146
PSTN dial tone permissible drop
time
4147
PSTN wait interval
160 ms
4148
Ringback tone detection time
20 ms
Detection is disabled if this
contains FF.
4149
PSTN busy tone upper frequency
limit (HIGH)
Hz (BCD)
If 4149 is FF, detection is
disabled. See Note 2.
414A
PSTN busy tone upper frequency
limit (LOW)
414B
PSTN busy tone lower frequency
limit (HIGH)
414C
PSTN busy tone lower frequency
limit (LOW)