SERVICE CALL CONDITIONS
B079/B082 4-8
SM
Code No.
Symptom
Possible Cause
LCT tray malfunction
510 C
1) The LCT lift sensor does not
activate for more than 18
seconds after the LCT lift motor
turned on.
2) The LCT lower limit sensor does
not activate for more than 18
seconds after the LCT lift motor
turned on.
3) The LCT lift sensor is already
activated when the LCT lift
motor turns on.
4) After the paper end sensor is
actuated while the tray is
raising, the upper limit sensor is
not actuated within 5 s. A
message is displayed to remind
the user to set the paper and
tray control halts. Resetting the
display is done by opening and
closing the LCT door.
5) The 4) state has been detected
3 times in succession.
LCT lift motor defective or
disconnected.
Upper limit sensor defective or
disconnected
Pick-up solenoid defective or
disconnected
Paper end sensor defective
520
Fusing/Feed-Out Motor Error
C
The PLL lock signal remains LOW for 2
s while the feed development motor is
operating.
Motor lock caused by overload.
Motor driver defective.
Fusing thermistor open
541 A
The fusing temperature detected by the
thermistor was below 7
°
C (44.6
o
F) for 5
seconds, or 2 seconds after reaching
45
o
C (113
o
F) the temperature does not
reach an additional 15
o
C (59
o
F) after
checking five times at 0.1 intervals.
Fusing thermistor disconnected
Fusing thermistor connector defective
Fusing thermistor damaged or warped
Fusing temperature –15% less than the
standard input voltage
Fusing temperature warm-up error
542 A
The fusing temperature does not reach
the fusing standby temperature of 45
o
C
(113
o
F) within 9 seconds for the B079
(35 cpm) 14 seconds for the B082 (45
cpm) after switching on the main power
or closing the front cover, or 40
seconds after reaching 50
o
C the fusing
roller does not reach warm-up
temperature.
Fusing lamp defective
Poor fusing unit connector
Thermistor warped or broken
Thermostat has tripped
BICU defective
Power supply board defective
Fusing overheat error (software
detection)
543 A
A fusing temperature of over 230
°
C
(446
o
F) is detected for 5 seconds by the
fusing thermistors at the center or at
either end of the fusing roller.
Power supply unit defective
I/O board (IOB) defective
BICU defective
Fusing thermistor defective
Summary of Contents for B079
Page 1: ...B079 B082 SERVICE MANUAL 001634MIU RICOH GROUP COMPANIES ...
Page 2: ......
Page 3: ...B079 B082 SERVICE MANUAL RICOH GROUP COMPANIES ...
Page 4: ......
Page 5: ...B079 B082 SERVICE MANUAL 001634MIU ...
Page 6: ......
Page 8: ......
Page 10: ......
Page 12: ......
Page 26: ......
Page 28: ......
Page 29: ...INSTALLATION ...
Page 30: ......
Page 101: ...PREVENTIVE MAINTENANCE ...
Page 102: ......
Page 107: ...REPLACEMENT AND ADJUSTMENT ...
Page 108: ......
Page 196: ......
Page 197: ...TROUBLESHOOTING ...
Page 198: ......
Page 221: ...Trouble shooting SERVICE CALL CONDITIONS SM 4 23 B079 B082 INTENTIONALLY LEFT BLANK ...
Page 225: ...SERVICE TABLES ...
Page 226: ......
Page 330: ......
Page 331: ...DETAILED SECTION DESCRIPTIONS ...
Page 332: ......
Page 436: ......
Page 437: ...SPECIFICATIONS ...
Page 438: ......
Page 448: ......
Page 449: ...BOOKLET FINISHER B546 ...
Page 450: ......
Page 497: ...AUTO REVERSE DOCUMENT FEEDER B541 ...
Page 498: ......
Page 525: ...LARGE CAPACITY TRAY B543 ...
Page 526: ......
Page 528: ......
Page 543: ...PAPER TRAY UNIT B542 ...
Page 544: ......
Page 546: ......
Page 565: ...1 BIN TRAY B544 ...
Page 566: ......
Page 568: ......
Page 576: ......
Page 577: ...1000 SHEET FINISHER B408 ...
Page 578: ......
Page 580: ......
Page 605: ...TWO TRAY FINISHER B545 ...
Page 606: ......
Page 643: ...BRIDGE UNIT B538 ...
Page 651: ...PRINTER OPTION B548 ...
Page 652: ......
Page 703: ...FAX OPTION B547 ...
Page 704: ......
Page 708: ......
Page 851: ...TECHNICAL SERVICE BULLETINS ...
Page 853: ...BRIDGE UNIT B538 ...
Page 908: ...Trouble shooting SERVICE CALL CONDITIONS SM 4 23 B079 B082 INTENTIONALLY LEFT BLANK ...
Page 941: ...FIRMWARE HISTORY ...