2. 2.ADF
Parameter
Formula
RAM
Address
Unit
Initial
Setting
W1
This parameter changes the start bit of the
main scan.
To increase the margin by X mm:
New setting = Current s X/0.508
To decrease the margin by X mm:
New setting = Current s X/0.508
8002A2(H) 0.508mm
02(H)
(02to04)
W2
Not adjustable
L1
This parameter changes the number of tx
motor steps after the scan line sensor is
activated.
To increase the margin by x mm:
New setting = Current s 7.875x
To decrease the margin by x mm:
New setting = Current setting - 7.875x
Initial setting of L1: 2 mm
800296(H)
(low)
800297(H)
(high)
1
7.875
mm
3F(H)
(0to200)
L2
Not adjustable (Original length - L1 - L3)
L3
This parameter changes the number of tx
motor steps after the scan line sensor is
deactivated.
To increase the margin by x mm:
New setting = Current setting - 7.875x
To decrease the margin by x mm:
New setting = Current s 7.875x
Initial setting of L3: 2 mm
800298(H)
(low)
800299(H)
(high)
1
7.875
mm
5C(H)
(0to200)
H523R562.WMF
REPLACEMENT AND ADJUSTMENT
June 10th, 1997
IMAGE ADJUSTMENT
6 - 38
Summary of Contents for Aficio FX10
Page 1: ...LFO AFICIO FX10 SERVICE MANUAL June 10th 1997 Subject to change...
Page 244: ...0RGHO 2 XURSH UDQFH VLD...
Page 246: ...2 19 1 EXTERIOR 1...
Page 248: ...4 28 30 29 2 EXTERIOR 2...
Page 250: ...6 3 CASSETTE...
Page 252: ...8 4 ADF UNIT 1...
Page 254: ...10 5 ADF UNIT 2...
Page 256: ...12 6 SCANNER 1...
Page 258: ...14 7 SCANNER 2...
Page 260: ...16 8 LASERUNIT...
Page 262: ...18 9 PAPER FEED SECTION...
Page 264: ...20 10 DEVELOPMENT UNIT...
Page 266: ...22 39 40 41 11 FUSING UNIT...
Page 268: ...24 12 PAPER EXIT SECTION 1...
Page 270: ...26 13 FRAME AND ELECTRICAL SECTION 1...
Page 272: ...28 26 14 FRAME AND ELECTRICAL SECTION 2...
Page 274: ...30 15 OPTION CASSETTE...
Page 276: ...34 PARTS INDEX...